2.0 Marine Diagnostics
46
Reference Manual
1- Mercury Marine
You can use the Fault Status function to display the active or history
status of ignition, injectors, pumps, sensors, switches, miscellaneous
items, limit modes or break-in status.
Make sure that the SELECT FUNCTION menu screen is displayed on
the DDT.
Select Function:
1–DATA MONITOR
2–FAULT STATUS
3–SYSTEM INFO
↓
FAULT STATUS has been organized in a way by which all faults can
be viewed from a single display area. For example: if a sensor fault
occurs while connected to the ECM, LED 4 will light.
Press the 2 key
FAULT
ACTIVE
BREAK–IN
YES
STAR OVERHEAT
NO
MAP INPUT LO
YES
All LED (1–8) supported faults will be displayed in the FAULT STATUS
display area. When a fault is currently active the YES message will
appear. If the fault corrects itself while the user is still connected to the
ECM, the message will change to NO. The message No would
indicate that a past history event occurred with that specific device. NO
is usually an indication of an intermittent connection problem. Faults
are also stored in the Freeze Frame buffers. See the section on Freeze
Frame for more details. If there are no faults active, the message
NONE will be displayed in the FAULT STATUS screen.
FAULT
ACTIVE
NONE
Press F2, 1
Press
To EXIT
Summary of Contents for SmartCraft Systems
Page 9: ...Preface 7 Reference Manual NOTES...
Page 28: ...1 0 Introduction 26 Reference Manual NOTES...
Page 29: ...2 0 Marine Diagnostics 27 Reference Manual OVERVIEW 1 Mercury Marine...
Page 98: ...2 0 Marine Diagnostics 96 Reference Manual NOTES...
Page 107: ...3 0 Glossary of Terms 105 Reference Manual NOTES...