EN
.
42
Parameter no. 61
–
Too high temperature limit
This parameter determines the temperature at which the device sends a command to the
associated device, to turn ON device or to turn OFF device.
Values (size is 2 byte dec):
•
default value 700 (too high temperature limit is 70.0 °C)
•
1 - 2120
NOTE1: Too high temperature limit is used with Association Group 3.
NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is
1
–
1000 (0.1
°C –
100.0
°C, resolution 0.1
°C)
NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is
322
–
2120 (32.2
°F –
212.0
°F, resolution 0.1
°F)
NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit
values will be converted to Celsius degrees. Due to conversion algorithm please be advised that
configuration value could drift when converting values back and forth.
Parameter no. 63
–
Output switch selection
Set value determines the type of the device connected to the on/off output. The output type
can be normally open (NO) or normally closed (NC).
Values (size is 1 byte dec):
•
default value 0
•
0 - When switch/device is off the output is 0V (NC).
•
1 - When switch/device is off the output is 240V or 24V (NO).