EN
.
34
12. Associations
Use associations for direct communication between the Flush On/Off Thermostat 2 and other
devices within your Z-Wave network without the need of your primary gateway (hub).
Association Groups:
Root device:
Group ID
Name
Allowed
nodes
Description
1
Lifeline
5
Supports the following commands:
•
Device Reset Locally: triggered upon request,
•
Sensor multilevel report: triggered upon temperature
change,
•
Meter report: triggered upon energy consumption change
according to configuration parameters 40, 42,
•
Notification report: triggered upon current overload
detection,
•
Thermostat mode: triggered upon thermostat mode change
•
Thermostat operating state: triggered upon thermostat
operating state (Idle, Heating, Cooling)
2
Change
of output
Q
5
Supports the following command:
•
Basic set: triggered by change of output Q
3
Basic
on/off
too high
too low T
5
Supports the following command:
•
Basic set: triggered when actual temperature reaches Too
High or Too Low temperature limit;
Heat mode: when temperature reaches Too High
Temperature Limit reports OFF (0x00), when temperature
reaches Too Low Temperature Limit reports ON (0xFF).
Cool mode: when temperature reaches Too High
Temperature Limit reports ON (0xFF), when temperature
reaches Too Low Temperature Limit reports OFF (0x00).
Thermostat off mode reports OFF (0x00) on both limits
reached.
Hysteresis is 1°C.
4
Sensor
multilevel
report
5
Supports the following command:
•
Sensor multilevel report: triggered by change of temperature
for threshold defined in configuration parameter 120