Parameter no. 43
–
Hysteresis Upper temperature offset
This parameter defines minimum temperature difference between real measured temperature
and set-point temperature to turn device on in heat mode or turn device off in cool mode.
Values (size is 2 byte dec):
•
default value 5
(0.5 °C)
•
0
–
450
NOTE1: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is 0
–
250 (0.0
°C –
25.0
°C, resolution 0.1
°C)
NOTE2: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is
0
–
450 (0.0
°
F
–
45.0
°
F, resolution 0.1
°
F)
NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that Fahrenheit
values will be converted to Celsius degrees. Due to conversion algorithm please be advised that
configuration value could drift when converting values back and forth.