Application Setup
Intelligent Electric Vehicle Chargepoints
QUBEVSM-V01-R0 Installation and Operation Manual
Page
29
of
42
February 2023
6. Tap the
Set Current (A)
label.
7. Ignore any entries that may already
displayed on screen. The figures shown
will not take effect until tapping to
confirm the new entry.
8. Select on the screen, the maximum
current that will be drawn by the
charger.
x
This must be the same as the
setting made with the DIP switches
inside the charger and should be
shown on the back of this manual.
x
Setting range is 6 - 32A.
9. Tap
Confirm
to enter the figure into the
system. The charger will beep twice to
acknowledge the setting.
Figure 23 Maximum Charger Output Amp Selection
NOTES:
x
To prevent sudden spikes of demand overloading the system, load balancing activates at
5A below the point set in the application.
x
If load balancing is in place but not configured, the
factory default is 45A
. If the current
drawn by the property and charger reaches 40A the load balancing system will decrease
the amount of power available for charging in an attempt to prevent an overload of the
electricity system.
x
Do NOT set the load balancing figures above that of the property fuse or the maximum
charging current of the charger (32A is the charger default but it may have been decreased
by the installer by use of the DIP switches to prevent overloading the power supply).