10.3. Self-lock vs. latching mode
The G022P allows for two different working modes; self-lock control and latching control. Self-lock allows for the
usual function of the relay where a command from the operator or the device to change is needed. If input from an
alarm then the relay will stay locked on until the command “
EXTRT
” is sent to the device from the operator (this is
also the same for latching mode).
With latching controls the device will return to its normal status after a period of seconds determined by the user.
This is useful for output devices that don‟t need or want to be on for a long time after they have been turned on. For
example alarm horns which might only need to be on for 12 seconds to alert the user.
Figure 8: Relay working mode configurations
Self-lock control
– normal operation of relay on or off by
command from user or device timer
Latching control
- which means relay go back to normal status
after a period of (3, 6, 9 or 12) Seconds.
Relay 1 working mode setting
Relay 2 working mode setting