Chapter 2 Messages
Supported SCSI Messages
Quantum ATL SuperLoader Software Interface Guide
23
Table 8 Transfer
Rates
The minimum supported value for Transfer Period is 0Ah when
the bus is operating in LVD mode. When operating in HVD or
Single-Ended mode, the minimum Transfer Period value is 0Ch.
The SuperLoader SDLT 220 and SuperLoader SDLT 320 Transfer
REQ/ACK offset may be any value between 0 and 62. A value of 0
indicates asynchronous transfers. A request with a value greater
than 62 will cause the device to return a request for 62.
The SuperLoader DLT1 Transfer REQ/ACK offset may be any
value between 0 and 15. A value of 0 indicates asynchronous
transfers. A request with a value greater than 15 will cause the
device to return a request for 15.
The SuperLoader LTO only supports a Transfer REQA/ACK offset
of 0. This indicates asynchronous transfers.
Wide Data Transfer
Request Extended
Message (03h)
2
The following figure illustrates the message format.
Transfer
Period
Transfer Rate
0Ah
40 MHz, 25 nsec Transfer Period
0Bh
33 MHz, 30.3 nsec Transfer Period. LTO and SDLT uses 37.5 nsec period.
0Ch
20 MHz, 50 nsec Transfer Period
0Dh – 5Dh
(4 * Transfer Period) nsecs.
Summary of Contents for ATL SuperLoader ATL
Page 1: ...ATL SuperLoader DLT and ATL SuperLoader LTO Software Interface Guide 81 60220 01 A02...
Page 18: ...Preface Document Conventions xviii Quantum ATL SuperLoader Software Interface Guide...
Page 44: ...Chapter 2 Messages Supported SCSI Messages 26 Quantum ATL SuperLoader Software Interface Guide...