CubiScan 125 Command Set
Communications Protocol
88
CubiScan 125
Factor Toggle
This command is used to set the dimensional factor to either domes-
tic or international.
3
1
Neg. Acknowledge
Alpha
(N)
4Eh
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Pos
Len
Description
Type
Range
ASCII
Pos
Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Fact. Toggle Command
Alpha
(F)
46h
3
1
Dom. / Int'l
Alpha
(D/I)
44h or 49h
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Fact. Toggle Command
Alpha
(F)
46h
3
1
Acknowledge
Alpha
(A)
41h
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Negative Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Fact. Toggle Command
Alpha
(F)
46h
3
1
Neg. Acknowledge
Alpha
(N)
4Eh
Summary of Contents for CubiScan 125
Page 8: ...Table of Contents iv CubiScan 125 Notes...
Page 39: ...Setup Connecting to a Computer or Network CubiScan 125 29 13 Click the Hardware tab...
Page 44: ...Setup Checklist Setup 34 CubiScan 125 Notes...
Page 90: ...Computer Error Messages Troubleshooting 80 CubiScan 125 Notes...
Page 124: ...Parts List 114 CubiScan 125 Notes...