Communications Protocol
CubiScan 125 Command Set
CubiScan 125
95
Scale Calibration Code Descriptions:
SA01
Clear the CubiScan
SA02
Place Test Weight in Corner
SA03
Scale Calibration Complete
Test
This command causes the CubiScan 125 to reply with an error code.
A response of TA00 means that the CubiScan 125 is ready and
responding to transmissions from the host. If the host receives no
response from the control unit after sending this command, an error
condition exists in the communications between the host and con-
troller.
Pos
Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Self Test Command
Alpha
(T)
54h
3
1
End of Text
Control
(ETX)
03h
4
1
Carriage Return
Control
(CR)
0Dh
5
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Self Test Command
Alpha
(T)
54h
3
1
Acknowledge
Alpha
(A)
41h
4
2
Identifier
Numeric
(00-99)
6
1
End of Text
Control
(ETX)
03h
7
1
Carriage Return
Control
(CR)
0Dh
8
1
Line Feed
Control
(LF)
0Ah