TCP/IP Communications Setup Command Set
Communications Protocol
110
CubiScan 125
Pos
Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Set Command
Alpha
(@)
40h
3
1
Gateway Address Command
Alpha
(G)
47h
4
7-15
or n
IP Address
Alpha
(0.0.0.0) to
(255.255.255.255)
4+n
1
End of Text
Control
(ETX)
03h
5+n
1
Carriage Return
Control
(CR)
0Dh
6+n
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Set Command
Alpha
(@)
40h
3
1
Gateway Address Command
Alpha
(G)
47h
4
1
Acknowledge
Alpha
(A)
41h
5
1
End of Text
Control
(ETX)
03h
6
1
Carriage Return
Control
(CR)
0Dh
7
1
Line Feed
Control
(LF)
0Ah
Negative Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Set Command
Alpha
(@)
40h
3
1
Gateway Address Command
Alpha
(G)
47h
4
1
Neg. Acknowledge
Alpha
(N)
4Eh
5
1
End of Text
Control
(ETX)
03h
6
1
Carriage Return
Control
(CR)
0Dh
7
1
Line Feed
Control
(LF)
0Ah
Summary of Contents for CubiScan 125
Page 8: ...Table of Contents iv CubiScan 125 Notes...
Page 39: ...Setup Connecting to a Computer or Network CubiScan 125 29 13 Click the Hardware tab...
Page 44: ...Setup Checklist Setup 34 CubiScan 125 Notes...
Page 90: ...Computer Error Messages Troubleshooting 80 CubiScan 125 Notes...
Page 124: ...Parts List 114 CubiScan 125 Notes...