No Response When You Turn Power On
Troubleshooting
78
CubiScan 125
No Response When You Turn Power On
If there is no response when you power on the CubiScan 125, do the
following:
1. Verify that the AC power cord is pressed firmly into the power
socket (on the left side of the controller box).
2. Check the fuse in the fuse drawer next to the power switch.
3. Verify that the AC power source is working properly.
Contact Quantronix if you require additional help.
Readings Are Not Accurate
If you suspect that the CubiScan 125 readings are inaccurate, do the
following:
1. Zero the CubiScan 125 by making sure the platform is free of
all objects and then selecting
Zero
from the toolbar or Tools
menu in Qbit. (If a computer is not connected, tap the
[Zero]
button on the touch screen.)
2. Move the CubiScan 125 if it is located close to open freight
doors or where hot air is blowing on it. Extreme changes in tem-
perature and humidity can affect the accuracy of the CubiScan
125. Refer to “Placement” on page 8 for information.
3. Recalibrate the CubiScan 125. Refer to page 59 for instructions.