CubiScan 125 Command Set
Communications Protocol
90
CubiScan 125
Measure
Receipt of this command causes the CubiScan 125 to measure and
weigh the package using the ultrasound sensors. The CubiScan 125
immediately formats the data collected and transmits it to the host
computer.
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Pos
Len
Description
Type
Range
ASCII
Pos
Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Measure Command
Alpha
(M)
4Dh
3
1
End of Text
Control
(ETX)
03h
4
1
Carriage Return
Control
(CR)
0Dh
5
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Measure Command
Alpha
(M)
4Dh
3
1
Acknowledge
Alpha
(A)
41h
4
1
CubiScan/Host Originated
Alpha
(C/H)
43h or 48h
5
6
City Code
Alpha
000000-ZZZZZZ
11
1
Comma
Alpha
(,)
2Ch
12
1
Length Identifier
Alpha
(L)
4C
13
5
Length
Numeric
000.0-999.9*
18
1
Comma
Alpha
(,)
2Ch
19
1
Width Identifier
Alpha
(W)
57h
Summary of Contents for CubiScan 125