CubiScan 125 Command Set
Communications Protocol
86
CubiScan 125
Dimension Calibration
This function is required when one of the sensors is replaced or
moved, when a new controller is installed, or for routine calibration.
This command causes the CubiScan 125 to reply with a dimension
calibration code each time it is issued. This command must be
issued FIVE times to complete sensor calibration. Dimension cali-
bration codes are defined below.
Pos
Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Dim.Calibration
Alpha
(D)
44h
3
1
End of Text
Control
(ETX)
03h
4
1
Carriage Return
Control
(CR)
0Dh
5
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Dim. Calibration
Alpha
(D)
44h
3
1
Acknowledge
Alpha
(A)
41h
4
2
Identifier
Numeric
(00-99)
6
1
End of Text
Control
(ETX)
03h
7
1
Carriage Return
Control
(CR)
0Dh
8
1
Line Feed
Control
(LF)
0Ah
Negative Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Dim. Calibration
Alpha
(D)
44h
3
1
Neg. Acknowledge
Alpha
(N)
4Eh
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Summary of Contents for CubiScan 125
Page 8: ...Table of Contents iv CubiScan 125 Notes...
Page 39: ...Setup Connecting to a Computer or Network CubiScan 125 29 13 Click the Hardware tab...
Page 44: ...Setup Checklist Setup 34 CubiScan 125 Notes...
Page 90: ...Computer Error Messages Troubleshooting 80 CubiScan 125 Notes...
Page 124: ...Parts List 114 CubiScan 125 Notes...