INSTALL GUIDE
v20.4
Step 18) Initial cleaning of the softener mineral tank.
f) SLOWLY turn open the INLET side of the softener bypass valve (opens
clockwise) until the mineral tank fills with water.
i)
Once the tank is full, the water will stop running.
g)
SLOWLY
turn open the OUTLET side of the softener bypass valve (opens
counter-clockwise).
h) Open the nearest softened treated cold water faucet or hose bib and run the
water until it shows clear.
i)
Use a container to view the water clarity. (This is to bleed out the resin’s
color and air. Let the water run until the water shows clear in the
container. Once the water runs clear into the container, turn off the faucet.
Your new softener is ready.)
i) Once the water runs clear into the container, turn off the faucet or hose bib.
38