Fig. I-29: CAS Signaling Wizard - page 2
From this page, signaling type settings of the timeslot(s) might be configured:
Allowed Call Type is used to select the allowed call directions: incoming, outgoing or both.
Signaling Type allows selecting the CAS signaling type.
Please Note:
R2 signaling (compelled and non-compelled) can only be used with an E1 in-
terface in User mode. Independent on the selection in this drop down list, Quadro with the
T1 interface in the CAS mode is unable to detect the busy tone on the destination side. For
E1 interface in the CAS mode, busy tone will be detected only for R2 compelled and non-
compelled (both with and without ANI) signaling types.
Force Update Timeslots checkbox can be optionally selected in order to apply new settings
immediately. This will force the timeslot(s) to be restarted and any active connection on the
selected timeslot(s) will be interrupted.
Please Note:
Quadro does not support the Forward Digit selected on the CO when acting
in the User mode with CAS Loop Start signaling type.
Get PSTN/PBX Error Message checkbox enables notification message in case of outgoing
calls to unreachable, incorrect or non existent destination.
When Generate Progress Tone to PSTN/PBX checkbox is selected, Quadro generates
ring tones to incoming callers during E1/T1 call dialing. This feature is mainly applicable to 2-
stage dialing mode.
Enable Echo Cancellation checkbox enables the echo cancellation mechanism on the se-
lected timeslot(s).