Figure 4.15
Three Elbows
INSTALLED
HORIZONTALLY
H
3
H
1
H
2
V
1
3 Elbows to Max. Horizontal
V
1
Minimum
H
1
Minimum
H
1
Maximum
H
TOTAL
3 ft.
914 mm
6 in.
152 mm
6 in.
152 mm
2 ft.
610 mm
4 ft.
1.2 m
6 in.
152 mm
14 in.
356 mm
6 ft.
1.8 m
6 ft.
1.8 m
6 in.
152 mm
14 in.
356 mm
8 ft., 8 in.
2.6 m
8 ft.
2.4 m
6 in.
152 mm
14 in.
356 mm
11 ft., 4 in.
3.5 m
10 ft.
3.1 m
6 in.
152 mm
14 in.
356 mm
14 ft., 0 in.
4.3 m
12 ft.
3.7 m
6 in.
152 mm
14 in.
356 mm
12 ft., 10 in.
3.9 m
16 ft.
4.9 m
6 in.
152 mm
14 in.
356 mm
10 ft., 4 in.
3.1 m
20 ft.
6.1 m
6 in.
152 mm
14 in.
356 mm
7 ft., 10 in.
2.4 m
24 ft.
7.3 m
6 in.
152 mm
14 in.
356 mm
5 ft., 4 in.
1.6 m
28 ft.
8.5 m
6 in.
152 mm
14 in.
356 mm
2 ft., 10 in.
864 mm
Note
: As vertical pipe increases, a flue restrictor may be
required.
Note:
A derating orifice is required with this application and is
included in the Rear Vent Kit.
CAUTION
!
VENTING STRAIGHT OUT THE REAR WITHOUT
VERTICAL RISE IS PROHIBITED