Quadra-Fire • TOPAZ-MBK-IPI, TOPAZ-D-PMH-IPI, TOPAZ-D-MBK-IPI, TOPAZ-D-CSB-IPI Installation Manual • 2341-980_R10 • 11/15
19
Figure 4.13
Top Vent - Vertical Termination - (continued)
Three Elbows
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V
2
Note
: As vertical pipe increases, a flue restrictor may be
required.
3 Elbows to Max. Horizontal
V
1
Minimum
V
1
+ V
2
Maximum
H
1
+ H
2
Maximum
3 ft.
914 mm
38 ft., 3 in.
11.7 m
2 ft.
610 mm
4 ft.
1.2 m
32 ft., 3 in.
9.8 m
6 ft.
1.8 m
6 ft.
1.8 m
28 ft., 3 in.
8.6 m
8 ft., 8 in.
2.6 m
8 ft.
2.4 m
24 ft.
7.3 m
11 ft., 4 in.
3.5 m
10 ft.
3.1 m
19 ft., 10 in.
6.0 m
14 ft.
4.3 m
12 ft.
3.7 m
21 ft., 9 in.
6.6 m
12 ft., 10 in.
3.9 m
16 ft.
4.9 m
25 ft., 6 in.
7.8 m
10 ft. 4 in.
3.1 m
20 ft.
6.1 m
29 ft., 6 in.
9.0 m
7 ft., 10 in.
2.4 m
24 ft.
7.3 m
33 ft., 3 in.
10.1 m
5 ft., 4 in.
1.6 m
28 ft.
8.5 m
37 ft., 3 in.
11.4 m
2 ft., 10 in.
864 mm