MT. VERNON E2 INSERT
M. LED Color Coding Chart and Explanation
The number of fl ashes between pauses is per one second unless otherwise indicated.
WARNING
Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Firepot fl oor open.
Do NOT store fuel:
• Closer than required clearances to combustibles to
appliance
• Within space required for loading or ash removal.
LED
Color
No. of Flashes
between pauses
Description Notes
Green
Steady ON while
priming feed tube
(max time
2 min utes)
Feed Motor is running
continuously.
(priming the feed tube)
When priming the feed system and fi lling the fi repot, DO
NOT OVERFILL FIREPOT FOR IGNITION
.
The unit will
automatically go into start up following the prime function.
Green
1x every 2
seconds
Unit is on standby
To start appliance, follow start up sequence.
Green
Blinks Continu-
ously
Appliance is in the start
up/ignition sequence or in
shutdown.
During shut down, the blowers will shut off when the
exhaust temperature has cooled.
Green
1X
Stage 1: Low heat
BTU Range: 1,8653 - 19,694
Average: 19,054
Green
2X
Stage 2: Med-Low heat
BTU Range: 22,102 - 23,506
Average: 22,735
Green
3X
Stage 3: Med heat
BTU Range: 30,778 - 32,680
Average: 31,603
Green
4X
Stage 4: Med-Hi heat
BTU Range: 38,576 - 42,914
Average: 40,665
Green
5X
Stage 5: Hi heat
BTU Range: 49,830 - 52,460
Average: 51,528
Red 1X
Empty
Hopper
Alarm
This alarm is caused by the fi re going out from lack of fuel.
Reset by turning to “OFF” then turn dial to desired setting.
Red 2X
Exhaust
Probe
Alarm
Failed component error. See troubleshoot ing section for
more information.
Red 4X
Missed
Ignition
There are a total of 2 tries per ignition sequence. If after
2 tries there is no rise in exhaust temperature this error
will occur. See the troubleshooting section for addi tional
information.
Red 6X
Encoder
Alarm
Failed Component Error: Exhaust Speed Sensor. See
troubleshooting guide
for more information
Red
8X
Exhaust Over
Temperature Alarm
See troubleshooting guide
for more information.