B. Sample of Serial Number / Safety Label

LOCATION:  Behind right cast side panel

Serial No.

Model 

Name

Test Lab & 
Report No.

Mfg. Date

S

A

M

P

L

E

Mt Vernon E2 Pellet Insert

R

SERIAL NO. / NUMÉRO DU

007059

Listed Solid Fuel Room Heater/Pellet Type.  Also suitable for Mobile Home Installation.  This appliance has 

been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 

814-23-909.
Appareil de chauffage de combustible solide/de type de boulettes.  Accepté dans l'installation dans les 

maisons mobiles.  Cet appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord 

avec OAR 814-23-9000 jusqu'à 814-23-909.

PREVENT HOUSE FIRES / 

PRÉVENTION DES FEUX DE MAISON

Install and use only in accordance with manufacturer's installation and operating instructions.  Contact local 

building or fire officials about restrictions and inspection in your area.

WARNING - FOR MOBILE HOMES:  Do not install appliance in a sleeping room.  An outside combustion air 

inlet must be provided.  The structural integrity of the mobile home floor, ceiling and walls must be maintained.  

Refer to manufacturer's instructions and local codes for precautions required for passing chimney through a 

combustible wall or ceiling.  Inspect and clean vent system frequently in accordance with manufacturer's 

instructions.  DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE.  Use a 3" 

or 4" diameter type "L" or "PL" venting system.
Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. Contactez le 

bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation 

dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil.

AVIS - Pour Les Maisons Mobiles:  Ne pas installer dans une chambre à coucher. Un tuyau extérieur de 

combustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est en usage. La structure 

intégrale du plancher, du plafond et des murs de la maison mobile doit être maintenue intacte.  Référez vous 

aux instructions du fabricant et des codes locaux pour les précautions requises pour passer une cheminée à 

travers un mur ou un plafond combustibles, et les compensations maximums.  Inspectez et nettoyez la 

cheminée fréquemment. Ne pas connecter cet appareil à une cheminée servant un autre appareil.  Utilisez 

systèm de ventilation "L" ou "PL" diamètre 76mm ou 102mm

Conforms to ASTM Std E1509-12. Certified to ULC S628-93. Room Heating Pellet BurningType,  (UM) 

84-HUD FOR USE ONLY WITH PELLETIZED WOOD  FUEL. Do not use any other type of fuel.  
Input Rating: 52,500 Btu's/hr.  Electrical Rating:115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps.  Route 

power cord away from unit.  Do not route cord under or in front of appliance.  Do not obstruct the space 

beneath the heater.
DANGER:  Risk of electrical shock.  Disconnect power supply before servicing.  Replace glass only with 5mm 

ceramic.  To start, turn dial control to desired setting and set thermostat above room temperature, the stove 

will light automatically.  To shutdown, turn dial control to OFF or set thermostat below room temperature.  For 

further instruction refer to owner's manual.  Keep viewing doors tightly closed during operation.  Keep viewing 

and ash removal doors tightly closed during operation.

Conforme à la norme ASTM E1509-12 Std. Certifié à la norme ULC S628-93. Room Heating Pellet Burning 

Type, (UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS.  N’utiliser aucun autre genre de 

combustible.  
Puissance de Rendement: 52,500 Btu's/hr.  

Puissance Électrique: 115 VAC, 60 Hz, Début 2.9 Amps, Courir 

2.45 Amps, Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en 

dessous de l'appareil.  Ne pas bloquer l’espace au dessous de l’appareil

.  

DANGER: Il y a risque de décharge électrique.  Déconnectez le fil électrique de la prise de contact avant le 

service.  Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.  

Pour commencer, tournez la molette de réglage à la température désirée et réglez le thermostat au-dessus de 

la température ambiante, le poêle s'allumera automatiquement. Pour éteindre, tournez la molette de réglage 

sur OFF ou réglez le thermostat dessous de la température ambiante.  Pour des instructions supplémentaires, 

référez vous au manuel du propriétaire.  Gardez la porte d'ouverture et la porte des cendres fermées 

hermétiquement durant l'opération.

7082-133

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP 

CHILDREN, CLOTHING AND FURNITURE AWAY. 

CONTACT MAY CAUSE SKIN BURNS.  SEE NAMEPLATE AND INSTRUCTIONS.  

CAUTION:

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. 

GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE 

L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES 

BRÛLURES À LA PEAU.  VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.  

ATTENTION:

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES

AS A BUILT-IN UNIT / COMME APPAREIL INSÉRÉ

A  Top of Hopper / Haut de la trémie 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

3 in  [76mm]

B  Side of Outside Skin / Côté de Enveloppe extérieure 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

2 in  [51mm]

C   Vent Pipe to Combustible / Des Conduits de combustible 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

3 in  [76mm]

D  Cast Side to Side Wall / Moulage Side à Wall Side 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

6 in  [152mm]

D

B

B

C

A

MASONRY OR ZERO CLEARANCE / DÉGAGEMENT DE LA MAÇONNERIE OU DÉGAGEMENT ZÉRO*

SIDE W

A

LL

 / MUR LA

TÉRAL

MANTEL / MANTEAU

C

A

B

D

E

A Cast Side to Side Wall / Moulage Side à Wall Side 

6 in  [152 mm]

B Insert top to face trim / Insérez le dessus de la garniture de façade 

0 in  [0 mm]

C Insert side to face trim / Insérez le côté de la garniture de façade 

0 in  [0 mm]

D Hearth extension from door opening / Prolongement d’âtre depuis l’ouverture de la porte devant 

6 in  [152 mm]

E Hearth extension from side of door opening / Prolongement d’âtre depuis le côté de l’ouverture de la porte 

6 in  [152 mm]

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with July 1990 particulate emission standards.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Made in U.S.A. of US and imported parts.

Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.

2013

2014

2015

JAN

FEB

MAR

APR

MAY

JUN

JUL

AUG

SEP

OCT

NOV

DEC

1445 North Highway, Colville, WA  99114

www.quadrafire.com

Manufactured by:Fabriqué par

Owners Manual

Install Manual

O-T L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Report:

 061-S-84-2 

A. Congratulations

Hearth & Home Technologies welcomes you to our tradition 
of excellence!  In choosing a Quadra-Fire appliance, you 
have our assurance of commitment to quality, durability, and 
performance.

This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 
advanced technology to achieve the optimum opera-

tion of our stoves, inserts and fi replaces.  And yet we are 
old-fashioned when it comes to craftsmanship.  Each unit 
is meticulously fabricated and gold and nickel surfaces are 
hand-fi nished for lasting beauty and enjoyment.  Our pledge 
to quality is completed as each model undergoes a quality 
control inspection.      

We wish you and your family many years of enjoyment in 
the warmth and comfort of your hearth appliance. Thank 
you for choosing Quadra-Fire.

NOTE:  Clearances may only be reduced by means 

approved by the regulatory authority having jurisdiction

and Welcome to the Quadra-Fire Family

!

Summary of Contents for MTVI-E2-CSB

Page 1: ...Keep clothing furniture draperies and other flammable materials away WARNING CAUTION Tested and approved for wood pellets only NOTE To obtain a French translation of this manual please contact your de...

Page 2: ...fil lectrique au dessus ou en dessous de l appareil Ne pas bloquer l espace au dessous de l appareil DANGER Il y a risque de d charge lectrique D connectez le fil lectrique de la prise de contact ava...

Page 3: ...ety 8 B Non Combustible Materials 8 C Combustible Materials 8 D Fuel Material and Fuel Storage 8 E Before Your First Fire 9 F Filling the Hopper 9 G User Dial Control 9 H Normal Startup Sequence 9 I F...

Page 4: ...uction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier...

Page 5: ...T VERNON E2 INSERT WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY 8 K N N OQ R U Z 8 88 U 8 U Q 8 N N Q Z R N U Q 8 R Z N N 88 N U Q 8 N O K WARRANTY EXCLUSIONS N Z N _ q _ q _...

Page 6: ...pellets will feed Wait for 2 minutes If the LIGHT did not turn solid green Turn dial back to OFF Unplug appliance plug it back in and repeat Priming is only needed for first fire or starting fire on...

Page 7: ...ies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supp...

Page 8: ...e from sawdust or wood by products Depending on the source material it may have a high or low ash content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Stan...

Page 9: ...happens the smoke should quickly disap pear During this stage as well as any part during the burn process the front door should not be opened HEAT SETTING HEAT SETTING O F F HI LO This startup cycle...

Page 10: ...tial operation Curing of high temperature paint Open windows for air circulation Odors may be irritating to sensitive individuals CAUTION WARNING HOT SURFACES Glass and other surfaces are hot during o...

Page 11: ...or in shutdown During shut down the blowers will shut off when the exhaust temperature has cooled Green 1X Stage 1 Low heat BTU Range 1 8653 19 694 Average 19 054 Green 2X Stage 2 Med Low heat BTU Ra...

Page 12: ...r the unit may have too much air To decrease the amount of combustion air rotate the trim dial towards zero one level at a time and allow 15 minutes for stabilization prior to making another adjustmen...

Page 13: ...manual operation of the TRANSMITTER If in the auto modes the THERMO operation will continue to operate normally To completely LOCK OUT the opera tion of the TRANSMITTER S operating signals the trans m...

Page 14: ...the Non burn season see troubleshooting section Is there a place to lubricate the blowers to quiet them down No The most often cause of noisy blowers is from the impellers becoming dirty over time Se...

Page 15: ...ce for your appliance Visit www quadrafire com to locate a dealer We recommend annual service by a qualified dealer A Proper Shutdown Procedure Turn dial control to OFF let appliance completely cool a...

Page 16: ...cleaned out more often than ash Ash Disposal Ashes should be placed in a steel container with a tight fitting lid The container of ashes should be moved outdoors immediately and placed on a non combus...

Page 17: ...re to vacuum the back of the baffle also Inspect the drop tube and remove any residue build up in the drop tube Figure 17 3 c Assemble the crevice tool from the micro cleaning kit to attach to a Shop...

Page 18: ...he appliance is allowed to cool b Open the front cast door and cycle the ash removal handle these should be inspected for functionality c Inspect for any degradation or deformation As the springs heat...

Page 19: ...he glass and firebox should be inspected periodically to make sure there is a good seal If the gasket is frayed or damaged replace with a new one 8 Cleaning Exhaust System Requires No Lubrication Freq...

Page 20: ...mation on how to handle a chimney fire In the event of a soot or creosote fire close the firebox door exit the building immediately and contact the proper fire authorities DO NOT under any circumstanc...

Page 21: ...2 5 Rock the top of the blower slightly and lift up The blower will pass out the left side of the appliance Note You may need to loosen the surround to move it out of the way 6 Install replacement blo...

Page 22: ...p disc is tripped Check to make sure convection blower wires are connected and reset snap disc located on RH side of appliance Clean inspect convection blower and convection air path Feed System is ja...

Page 23: ...er fails to shut off Wire short between blower and ground Control board is defective Repair wire and replace control board Exhaust blower fails to start and or red flashes 6X indicating a exhaust enco...

Page 24: ...t trim per trim dial instructions Feed Motor locked on Follow corrective action for feed motor not turning off Excessive fuel spilling over the fire pot and or excessive flame Dirty Appliance Clean un...

Page 25: ...terminal end to control board Failed component Replace exhaust probe securing it to exhaust blower housing keeping wire away from hot surfaces 4 Red Flashes Missed Ignition Hopper empty Fill the hopp...

Page 26: ...Convection Blower The convection blower is mounted at the bottom left of the appliance The convection blower pushes heated air through the heat exchange system into the room 4 Feed System The feed sy...

Page 27: ...ON INSERT E2 Beginning Manufacturing Date Dec 2014 Ending Manufacturing Date Active Pellet Insert MTVI E2 CSB MTVI E2 MBK MTVI E2 PMH Part number list on following pages 11 13 40 39 38 37 36 35 34 33...

Page 28: ...06P 3 Top Matte Black 7036 101MBK Porcelian Mahogany 7036 101PMH Sienna Bronze 7036 101CSB 4 Catch Clip 7036 146 5 Elbow Catch 7000 393 6 Bracket Catch 7036 145 7 Backer Side Window 414 0280 8 Side Ma...

Page 29: ...ner 7034 136 19 2 Glass Assembly 21 W x 14 H 7034 007 Y 19 3 Hinge Female 450 2910 19 4 Door Latch Assembly 413 5200 Gasket Channel 3 Mm X 32 Field Cut to Size 10 Ft 7000 377 10 Y 20 Ash Pan Door 7034...

Page 30: ...Blower SRV7080 106 Y Gasket Blower Combustion Between Housing Stove SRV7080 117 Y Gasket Motor Blower Combustion Between Housing Motor SRV7080 107 Y 32 Snap Disc L250 Manual Reset SRV230 1290 Y 33 Fl...

Page 31: ...B Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 3 Vent Adapter 3 4 811 0720 Vent Adapter 90 cleanout TPVNT 6 Vent Adapter Cleanout 811 0620 Surround Std Panel For Cast Trim SP MTVS CST Component Pac...

Page 32: ...ille WA 99114 Division of HNI INDUSTRIES Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com This produc...

Reviews: