background image

 30 

 

 

 

 

                        7082-132C 

 

 

                             June 18, 2014

MT. VERNON E2 INSERT

Service Parts

R

MT VERNON INSERT-E2

Beginning Manufacturing Date: Dec 2014 

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. 

Hearth and 

Home Technologies does not sell directly to consumers

. Provide model number and serial number when 

requesting service parts from your dealer or distributor.

Stocked

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

24

Gasket, Rope, Ash Door

SRV7034-178

Y

25

Bottom

Matte Black

7036-109MBK

Sienna Bronze

7036-109CSB

Mahogany

7036-109PMH

26

Wireless Thermostat Receiver

SRV7080-109

Y

Wireless Thremostat

SRV7080-108

Y

27

Control Board

SRV7080-050

Y

Wire Harness

SRV7080-129

Y

28

Vacuum Switch

SRV7000-531

Y

Vacuum Hose

3 FT cut ro fi t

SRV7000-373

Y

29

Latch Bracket Assembly

7034-049

Y

30

Control Panel Door Assembly w/ Control Panel Assembly

SRV7082-037

Control Panel Assembly

SRV7080-036

Y

31

Combustion Blower

SRV7080-106

Y

Gasket, Blower, Combustion                     (Between …)

...Housing & Stove

SRV7080-117

Y

Gasket, Motor, Blower, Combustion         (Between …)

...Housing & Motor

SRV7080-107

Y

32

Snap Disc, L250, Manual Reset

SRV230-1290

Y

33

Flue Collar Assembly

SRV7082-013

34

Gasket, Flue Adpator Flange

7036-180

Y

35

Top Vent Adapter

TPVNT-4

36

Convection Blower

SRV7080-105

Y

37

Feed Assembly

SRV7080-010

Y

Feed Spring Assembly (Only)

SRV7001-046

Y

Gasket, Feed Motor

7034-144

Feed Motor 

812-4421

Y

38

Elbow Catch

7000-393

39

Magnetic Switch

7000-375

Y

40

Bracket, Hopper Magnet

7036-149

Component Pack: (Owners Manual, Quick Start Guide, Heat Exchanger 
& Exhaust Cleaning Instructions, Warranty Card, Dvd “How To”, Wall 
Control & Harness, Power Cord, Leveling Nuts & Bolts, Firepot Clean-
Out Tool, Touch-Up Paint, and Label “If Fireplace Altered”)

Matte Black

SRV7082-040

Sienna Bronze

SRV7082-041

Mahogany

SRV7082-042

Cleanout Tool

414-1140

Y

Paint Touch-Up

Matte Black

812-0910

Sienna Bronze

TOUCHUP-CSB

Mahogany

855-1450

Power Cord

812-1180

Y

Heating Element Assembly 18” (Loop Igniter)

Pkg of 1 

SRV7000-462

Y

Pkg of 10

SRV7000-462/10

Y

Wing Thumb Screw 8-32 X 1/2

Pkg of 24

7000-223/24

Y

Wire Clip

7000-400/10

Y

Summary of Contents for MTVI-E2-CSB

Page 1: ...Keep clothing furniture draperies and other flammable materials away WARNING CAUTION Tested and approved for wood pellets only NOTE To obtain a French translation of this manual please contact your de...

Page 2: ...fil lectrique au dessus ou en dessous de l appareil Ne pas bloquer l espace au dessous de l appareil DANGER Il y a risque de d charge lectrique D connectez le fil lectrique de la prise de contact ava...

Page 3: ...ety 8 B Non Combustible Materials 8 C Combustible Materials 8 D Fuel Material and Fuel Storage 8 E Before Your First Fire 9 F Filling the Hopper 9 G User Dial Control 9 H Normal Startup Sequence 9 I F...

Page 4: ...uction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier...

Page 5: ...T VERNON E2 INSERT WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY 8 K N N OQ R U Z 8 88 U 8 U Q 8 N N Q Z R N U Q 8 R Z N N 88 N U Q 8 N O K WARRANTY EXCLUSIONS N Z N _ q _ q _...

Page 6: ...pellets will feed Wait for 2 minutes If the LIGHT did not turn solid green Turn dial back to OFF Unplug appliance plug it back in and repeat Priming is only needed for first fire or starting fire on...

Page 7: ...ies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supp...

Page 8: ...e from sawdust or wood by products Depending on the source material it may have a high or low ash content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Stan...

Page 9: ...happens the smoke should quickly disap pear During this stage as well as any part during the burn process the front door should not be opened HEAT SETTING HEAT SETTING O F F HI LO This startup cycle...

Page 10: ...tial operation Curing of high temperature paint Open windows for air circulation Odors may be irritating to sensitive individuals CAUTION WARNING HOT SURFACES Glass and other surfaces are hot during o...

Page 11: ...or in shutdown During shut down the blowers will shut off when the exhaust temperature has cooled Green 1X Stage 1 Low heat BTU Range 1 8653 19 694 Average 19 054 Green 2X Stage 2 Med Low heat BTU Ra...

Page 12: ...r the unit may have too much air To decrease the amount of combustion air rotate the trim dial towards zero one level at a time and allow 15 minutes for stabilization prior to making another adjustmen...

Page 13: ...manual operation of the TRANSMITTER If in the auto modes the THERMO operation will continue to operate normally To completely LOCK OUT the opera tion of the TRANSMITTER S operating signals the trans m...

Page 14: ...the Non burn season see troubleshooting section Is there a place to lubricate the blowers to quiet them down No The most often cause of noisy blowers is from the impellers becoming dirty over time Se...

Page 15: ...ce for your appliance Visit www quadrafire com to locate a dealer We recommend annual service by a qualified dealer A Proper Shutdown Procedure Turn dial control to OFF let appliance completely cool a...

Page 16: ...cleaned out more often than ash Ash Disposal Ashes should be placed in a steel container with a tight fitting lid The container of ashes should be moved outdoors immediately and placed on a non combus...

Page 17: ...re to vacuum the back of the baffle also Inspect the drop tube and remove any residue build up in the drop tube Figure 17 3 c Assemble the crevice tool from the micro cleaning kit to attach to a Shop...

Page 18: ...he appliance is allowed to cool b Open the front cast door and cycle the ash removal handle these should be inspected for functionality c Inspect for any degradation or deformation As the springs heat...

Page 19: ...he glass and firebox should be inspected periodically to make sure there is a good seal If the gasket is frayed or damaged replace with a new one 8 Cleaning Exhaust System Requires No Lubrication Freq...

Page 20: ...mation on how to handle a chimney fire In the event of a soot or creosote fire close the firebox door exit the building immediately and contact the proper fire authorities DO NOT under any circumstanc...

Page 21: ...2 5 Rock the top of the blower slightly and lift up The blower will pass out the left side of the appliance Note You may need to loosen the surround to move it out of the way 6 Install replacement blo...

Page 22: ...p disc is tripped Check to make sure convection blower wires are connected and reset snap disc located on RH side of appliance Clean inspect convection blower and convection air path Feed System is ja...

Page 23: ...er fails to shut off Wire short between blower and ground Control board is defective Repair wire and replace control board Exhaust blower fails to start and or red flashes 6X indicating a exhaust enco...

Page 24: ...t trim per trim dial instructions Feed Motor locked on Follow corrective action for feed motor not turning off Excessive fuel spilling over the fire pot and or excessive flame Dirty Appliance Clean un...

Page 25: ...terminal end to control board Failed component Replace exhaust probe securing it to exhaust blower housing keeping wire away from hot surfaces 4 Red Flashes Missed Ignition Hopper empty Fill the hopp...

Page 26: ...Convection Blower The convection blower is mounted at the bottom left of the appliance The convection blower pushes heated air through the heat exchange system into the room 4 Feed System The feed sy...

Page 27: ...ON INSERT E2 Beginning Manufacturing Date Dec 2014 Ending Manufacturing Date Active Pellet Insert MTVI E2 CSB MTVI E2 MBK MTVI E2 PMH Part number list on following pages 11 13 40 39 38 37 36 35 34 33...

Page 28: ...06P 3 Top Matte Black 7036 101MBK Porcelian Mahogany 7036 101PMH Sienna Bronze 7036 101CSB 4 Catch Clip 7036 146 5 Elbow Catch 7000 393 6 Bracket Catch 7036 145 7 Backer Side Window 414 0280 8 Side Ma...

Page 29: ...ner 7034 136 19 2 Glass Assembly 21 W x 14 H 7034 007 Y 19 3 Hinge Female 450 2910 19 4 Door Latch Assembly 413 5200 Gasket Channel 3 Mm X 32 Field Cut to Size 10 Ft 7000 377 10 Y 20 Ash Pan Door 7034...

Page 30: ...Blower SRV7080 106 Y Gasket Blower Combustion Between Housing Stove SRV7080 117 Y Gasket Motor Blower Combustion Between Housing Motor SRV7080 107 Y 32 Snap Disc L250 Manual Reset SRV230 1290 Y 33 Fl...

Page 31: ...B Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 3 Vent Adapter 3 4 811 0720 Vent Adapter 90 cleanout TPVNT 6 Vent Adapter Cleanout 811 0620 Surround Std Panel For Cast Trim SP MTVS CST Component Pac...

Page 32: ...ille WA 99114 Division of HNI INDUSTRIES Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com This produc...

Reviews: