Page 30
7005-151D
December 22, 2006
R
Mt. Vernon Pellet Stove
RR
D. Igniter Replacement
a. Shut down the appliance by turning down the thermostat
and let the appliance completely cool down
.
After the
appliance has cooled down, unplug it and remove the
ash drawer.
b. The wire leads to the igniter are connected to the
wire harness with 1/4 inch (6.35mm) male / female
spade connectors. These wires will pull forward
approximately 4 to 5 inches (102-127mm). Disconnect
the spade connections and remove the igniter from the
chamber. Remove the thumb screw and slide igniter
out.
c. Install new igniter into the chamber and replace the
screw. Re-connect the wires to the 2 leads with the
spade connectors.
d. Remove right side panel and pull wire leads back
toward the rear of the appliance to take-up the 4 to 5
inches (102-107mm) previously pulled out. This will
keep the wires out of the way of the ash drawer. Double
check that the igniter wires are clear of any movement,
i.e. ash drawer, firepot cleaning rod, cleaning slide
plates, etc.
f. Re-install the ash drawer and close the ash removal
door and then re-install the side panel and re-connect
the power.
Thumb Screw
Igniter
Figure 30.2
2. Exhaust Blower Replacement
• Frequency:
As needed
• By:
Quality Service Technician Recommended
• Task:
a. Follow instructions for removing the convection blower,
and outside air if applicable.
b. Remove the right side curtain.
c. Remove the wires connecting:
a. Vacuum switch - red & orange
b. Circuit breaker - gray & black
c. Electrical cord connector - black & double white
with green
d. Thermostat terminal - 2 yellow
e. Disconnect vacuum hose from the vacuum switch.
f. Remove the rear screen from the stove by removing
the 3 screws at the bottom and the 5 screws along the
top of the screen.
See Figure 29.5 on page 29.
e. Disconnect the double white and double blue wires from
the exhaust blower.
f. There is a removable plate on the exhaust blower. Loosen
the 6 screws in the keyhole shaped holes and rotate the
plate.
Figure 30.1
g. Remove the exhaust blower and gasket.
i. Re-install in reverse order.
NOTE: PRIOR TO REPLACING THE EXHAUST
BLOWER, THE CONVECTION BLOWER MUST BE
REMOVED. SEE PAGE 29.
Left Side Panel
Removed
Convection Blower
Exhaust Blower
Loosen screws &
remove blower
Figure 30.1
f i r e - p a r t s . c o m