Page 8
7005-151D
December 22, 2006
R
Mt. Vernon Pellet Stove
RR
Straight Back Against
Wall
Inches Millimeters
A
Back Wall to Appliance
2
51
B
Side Wall to Appliance
6
152
Corner Installation
Inches Millimeters
C
Walls to Appliance
2
51
Vertical Installation
Inches Millimeters
D
Back Wall to Flue Pipe
3
76
E
Side Wall to Appliance
6
152
F
Back Wall to Appliance
8
203
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
Corner Installation
Inches Millimeters
G
Walls to Appliance
2
51
H
Side Wall to Flue Pipe
3
76
Alcove Installation
Inches Millimeters
Minimum Alcove Height
43
1092
Minimum Alcove Side Wall
6
152
Minimum Alcove Width
40
1016
Maximum Alcove Depth
48
1219
Dimension to Corner
Inches Millimeters
I
Flue Center Line
10-3/8
264
J
Back of Top Vent Adapter
9-1/8
232
B. Clearances to Combustibles (UL and ULC)
D
E
F
A
B
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
WARNING
Failure to comply may cause house fire.
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
•
I
llustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design
preference.
C
C
G
G
H
H
J
I
CL
f i r e - p a r t s . c o m