Page 32
Quadra-Fire • Hudson Bay • 7003-121_R20 • 11/14
H. Blower Installation
KIT CONTENTS:
Blower; 2 female spade wire connectors.
TOOLS REQUIRED:
Powered screwdriver with a #2 Phillips
head bit.
The blower motor comes standard with two male spade
wire connectors. If your appliance has a different
connection, use the two female spade wire connectors
provided to modify the appliance wiring harness.
Figure 8.20 -
Disconnect power to the appliance. To access
the blower, open the door located on the front of the pedestal.
Remove the two screws holding the blower bracket in place.
Figure 8.21 -
Disconnect wires to the blower motor. Remove
the blower from the bracket.
Figure 8.22 -
Install the new blower by slipping grommets
over studs on the blower bracket. Reinstall the blower and
bracket. Connect the wires. Install screws. Restore power
to the appliance.
Figure 8.23 Blower Wiring Diagram
F = Female spade connector
M = Male spade connector
F
M
F
F
Thermal Disk
Fan Assembly
BLK
BLK
GRN
WHT
BLK
F
M F
M
WHT
Fan Speed Control
BLK
BLK
Strain Relief Bushing
Power Cord (110 VAC)
Ground
WHT
BLK