A. Recommendation for Wire
See B5 below for recommended maximum lead length (two
wire) when using wall thermostat/switch.
C. Standing Pilot Ignition System Wiring
This appliance
DOES NOT
require 110 VAC supply for
operation. A wiring diagram is shown in
Figure 7.1
on the
next page.
This appliance is equipped with a millivolt control valve.
B. Connecting to the Appliance
NOTE:
This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local codes,
with
National Electric Code ANSI/NFPA 70-latest edition
or
the
Canadian Electric Code, CSA C221.1.
1. This appliance may be used with a wall switch, wall
mounted thermostat and / or a remote control.
2. If using thermostat, use one compatible with a millivolt
gas valve system.
3. Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
4. Use low resistance thermostat wire for wiring from
ignition system to the wall switch and thermostat.
5. Use the following chart for wire sizing.
6. Keep wire lengths as short as possible by removing any
excess wire length.
7. Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
Wire Size
Max. Length
16 gauge
65 feet
18 gauge
40 feet
20 gauge
25 feet
22 gauge
18 feet
Shock hazard.
• This appliance is equipped with a three pronged
(grounding) plug for your protection against shock
hazard and should be plugged directly into a
properly grounded three prong receptacle. Do not
cut or remove the grounding prong from this plug.
Wire 110v to electrical junction box.
Do NOT wire 110v to the valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage
millivolt systems.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when it is
installed in locations such as in bathrooms or near sinks.
7
Electrical Information
WARNING
!
8. Ensure the thermostat is mounted level for accurate
readings.
9. The thermostat should be mounted on an inside wall
and not in direct line with the appliance convection air.
10. If the thermostat is located too close to the appliance,
you may need to set the temperature setting slightly
higher to maintain the desired temperature in your
home.
Do not connect this appliance to a thermostat serving
any other appliance.
Bedroom installation in Canada requires this appliance
to be connected to a thermostat.