background image

 22 

 

 

 

 

                       7014-258B 

 

 

 

     November 30, 2017

CB1200 FREESTANDING

CAUTION

Logs are FRAGILE.  Use extreme care when handling or 

cleaning logs.

D. Optional 

Log Set Placement Instructions

1.  Place the front log in first as shown in 

Figure 22.1

.  Place 

log between fire pot and face of appliance with charred 

area surrounding fire pot.

2.  Set  the  left  and  right  logs  onto  the  front  log,  placing  

the holes in the base of the left and right logs over the 

locating pins in front log.  See 

Figure 22.2.

  Ensure that 

the charred ends are facing the fire pot. 

Figure 22.1

NOTE:

  

Due to the abrasive nature of a pellet appliance fire, the logs 

are not covered under warranty.  Any placement variation 

other than shown here can cause excessive heat and shall 

void the appliance warranty.

LOCATING PINS

Charred Areas in the Back 

Top Log

Right 

Top Log, Left

Front Log 

Figure 22.2

Install Logo

E. Installing Logo

1.  Remove logo from packaging.
2.  The logo has 2 studs on the back.

3.   Install the logo on the lower left side of the center panel 

by pressing the 2 studs into the already drilled holes.  

See 

Figure 22.4.

Figure 22.3

F. Thermostat Installation and Operation

 

There is a 4 screw terminal block located on the back 

lower left corner of the stove directly above the power 

cord inlet.  The center 2 screws are for the thermostat 

wires (see 

Figure 23.1 on page 23

)

.  

The appliance comes standard with a wall thermostat and 25’ 

of wire.  If you need to run more than 25’ make sure you use 

a continuous strand of 18 to 22 gauge thermostat wire.  For 

optimum performance your thermostat should be located on 

an inside wall approximately 5’ up from the floor.

How to Install Your Wall Thermostat 

1.    Separate the body of the thermostat from the mounting 

plate by gently pulling the two pieces apart

2.  Connect your thermostat wire to the W and R terminals 

(see 

Figure 23.2 on page 23

)

3.  Screw the backer plate to the wall using the hardware 

included

4.  Snap the thermostat to the backer plate

5.  Connect the wires to the 2 center screws on the terminal 

block on the back of the product

Shock hazard.

•  Do NOT remove grounding prong from plug.

•  Plug directly into properly grounded 3 prong 

receptacle.

•  Route cord away from appliance.

• 

Do NOT route cord under or in front of appli

-

ance.

CAUTION

Summary of Contents for CB1200M-MBK

Page 1: ...allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing...

Page 2: ...4 B Thermostat Wall Control Location 5 C Tools And Supplies Needed 5 D Inspect Appliance and Components 5 E Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Clearances to...

Page 3: ...without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a fire hazard WARNING Fire Risk Hearth Hom...

Page 4: ...the installation Location of the appliance and chimney will affect performance Consideration must be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to mini...

Page 5: ...s location will have some affect on the appliance s operation Maximum wire length from appliance is 100 feet 30 48m continuous non spliced wire Recommended 20 gauge wire solid copper When located clo...

Page 6: ...ation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the a...

Page 7: ...ESTANDING Figure 7 1 Top View Figure 7 2 Side View Figure 7 3 Front View 6 1 4 159 8 203 8 203 25 3 4 654 27 5 8 702 8 204 25 3 4 654 28 1 2 724 31 5 8 803 28 1 2 725 21 1 4 539 10 3 8 264 3 Dimension...

Page 8: ...62 33 1 8 841 31 1 4 795 Figure 8 1 Top View with Top Vent Adapter TPVNT 1 and Offset Adapter 812 3570 Figure 8 2 Side View with Top Vent Adapter TPVNT 1 and Offset Adapter 812 3570 Figure 8 3 Top Vie...

Page 9: ...REESTANDING 2 3 8 62 2 3 4 69 3 7 8 100 6 1 4 159 8 203 8 203 15 51 8 398 14 357 Figure 9 1 Top View with Top Vent Adapter TPVNT 6 and Offset Adapter 811 0720 Figure 9 2 Side View with Top Vent Adapte...

Page 10: ...ack Wall to Appliance 7 5 191 Corner Installation Inches Millimeters G Side Wall to Flue Pipe 2 51 Installations with TPVNT 1 Top Vent Adapter with Heat Shield and Clean out TPVNT 6 Top Vent Adapter w...

Page 11: ...pipe shaded area to the wall thimble CANADA 47 3 4 in 26 1 4 in 21 1 2 in 41 3 8 in 6 in from the fuel door opening USA 1214mm 666mm 545mm 1051mm 152mm front door opening CANADA Must extend 51mm beyo...

Page 12: ...strations diagrams are not drawn to scale Actual installation may vary due to individual design preference D Alcove Figure 12 1 All minimums listed are to a combustible surface Figure 12 2 Minimum Max...

Page 13: ...lk paved driveway located on public property M 12 in Under an open veranda porch deck or balcony N See Note below Electric service above below or to the side location must not obstruct or interfere wi...

Page 14: ...t of the demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appli ance It may be necessary to add additional vent...

Page 15: ...mm diameter type L or PL venting system It can be vented vertically or horizontally 2 Mobile Home Approved for all Listed pellet vent If using the 3 inch 76mm vertical Top Vent Adapter Kit or the 3 to...

Page 16: ...F FEET 0 20 30 1 2 3 4 5 6 7 8 9 10 4 in 102mm Diameter Pipe Only 10 Example 1 Example 2 Example 1 If the equivalent length of pipe is 23 feet 7m with altitude of 8 000 feet 2438m you must use 4 inch...

Page 17: ...d for mobile home installa tions Must use 3 or 4 inch 76 102mm L or PL Listed pellet venting or Listed double wall pipe and a Quadra Fire Outside Air Kit in mobile homes NOTE In Canada where passage t...

Page 18: ...g Rain Cap 6 in 152mm Min Non combustible Hearth Pad 3 in 76mm Min 24 in 610mm Minimum 3 in to 3 in 76 76mm Top Vent Kit Clean out Cover All three installations are approved for mobile home installa t...

Page 19: ...pace Concrete Cap 1 in 25mm Clearance with Firestop 6 in 152mm Minimum Non Combustible Hearth Pad Sheathing 2 in 51mm Minimum 1 in 25mm Clearance Flashing Fireclay Flue Liner withAirspace Concrete Cap...

Page 20: ...utside termination cap with second hose clamp e Secure termination cap to outside surface f Secure trim ring to interior wall g Snip corners and remove plate Figure 20 1 h Align and secure collar asse...

Page 21: ...ppliance using the outer shield as a pattern make sure the assembly is vertical Figure 21 1 4 Install the 4 mounting screws 5 Install the vent pipe into the top vent adapter be sure to silicone all jo...

Page 22: ...2 studs into the already drilled holes See Figure 22 4 Figure 22 3 F Thermostat Installation and Operation There is a 4 screw terminal block located on the back lower left corner of the stove directly...

Page 23: ...REPLACE BATTERY warning begins flashing The warning flashes about two months before the batteries are depleted Even if the warning does not appear you should replace batteries once a year If batteries...

Page 24: ...CFR 3280 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 24 1 CAUTION Never draw outside combustio...

Page 25: ...November 30 2017 7014 258B 25 CB1200 FREESTANDING 8 Accessory List A Service Maintenance Log Date of Service Performed By Description of Service...

Page 26: ...26 7014 258B November 30 2017 CB1200 FREESTANDING Date of Service Performed By Description of Service...

Page 27: ...er Outside Air Kit Floor 411 1071 Hose Alum Flex 2 Inch x 3 Ft Qty 3 Ft Req SRV200 0860 Outside Air Cap Assembly 7001 044 Outside Air Collar Assembly SRV7001 045 Trim Plate Outside Air Kit 412 7100 Sm...

Page 28: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dea...

Reviews: