CB1200 FREESTANDING
6
Appliance Set-Up
A. Outside Air Kit Instructions
Included in Kit:
1 piece of 2 inch x 3 foot flex hose, 2 hose
clamps, 1 collar assembly, termination cap assembly, 1 trim
ring, 12 screws.
Tools Needed:
Phillips head screw driver; wire cutters;
hole saw or jig saw.
1. Rear Installation
a. Measure distance from floor to air vent opening in appli
-
ance and mark location on wall.
Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch
(76-89mm) opening on outside of house.
b. Use hose clamp to secure flex pipe to collar assembly.
c. Slide trim ring over flex pipe and run pipe through wall.
d. Attach hose to outside termination cap with second hose
clamp.
e. Secure termination cap to outside surface.
f. Secure trim ring to interior wall.
g.
Snip corners and remove plate.
Figure
20.1
.
h. Align and secure collar assembly with 2 of the 4 holes as
shown.
Figure
20.2.
CAUTION
Never draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
Flex Hose
Hose Clamp
Collar Assembly
Trim Ring
Termination
Cap Assembly
Hose Clamp
Air Intake Channel
(Discard)
Figure 20.2
Figure 20.1
Snip Corners
and remove
plate
NO
NO
Secure Collar
Screen
Install Cover Plate
Seal Pedestal with 26 in. Rope
Figure 20.4
Figure 20.3
2. Floor Installation
a. Remove rear screen and set aside.
b.
Install cover plate over hole in right rear floor.
c. Cut a 2 inch
minimum hole in the floor to accommodate
flex hose.
d. Attach hose to termination cap.
e. Place rope under pedestal to close off air leaks.