© 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380      Ph. 800-750-2723

THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.

Owner’s Instruction and Operation Manual

U.S. Environmental Protection Agency

Certified to comply with 2020 particulate 

emissions standards.

SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For 
your  safety,  follow  the  installation  instructions.  Never  use  make-shift  compromises 
during  the  installation  of  this  heater.  Contact  local  building  or  fire  officials  about 

permits, restrictions and installation requirements in your area. NEVER OPERATE THIS 
PRODUCT WHILE UNATTENDED.

CAUTION!  Please  read  this  entire  manual  before  you  install  or  use  your  new  room 

heater. Failure to follow instructions may result in property damage, bodily injury, or 

even death. Improper Installation Will Void Your Warranty!

Save These Instructions In A Safe Place For Future Reference.

 CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals 

including carbon monoxide, which is known to the 

State of California to cause cancer, birth defects, 

and/or other reproductive harm. For more 

information, go to 

www.P65warnings.ca.gov

VG2520-P •  VG2520-BP
VG2520-L •  VG2520-BL

853580H-1805K

R

Report Number: F19-487

Tested Per EPA Methods ALT-125, ASTM 

E2515, ASTM E3053 and CSA B415

Certified  to  UL  1482-2011  (R2015)  and 

ULC-S627-00-REV1

Mobile home approved (U.S. ONLY)

Model Numbers:

Содержание VG2520-BL

Страница 1: ...stallation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Future Reference CALIFORNIAPROPOSITION65WARNING This p...

Страница 2: ...bove are based on the EPA test protocol under specific test conditions Our advertised BTU s are based on the first hour of operation at high burn rate burning cordwood Combustible Wood Colors Black Flue Pipe Diameter 6 152 5mm Flue Pipe Type Standard Single Wall or Double Wall Black or Blued Steel 2100 F 650 C Minimum Chimney Height 12 3 7m Maximum Log Length 21 534mm Dimensions MODEL DEPTH WIDTH ...

Страница 3: ..._________________________________ If no Date of inspection of the existing chimney system _______________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in this ma...

Страница 4: ...WER ASSEMBLY The blower assembly must be disconnected from the source of electrical supply before attempting the installation The blower assembly is intended for use only with a stove that is marked to indicate such use Do not route the supply cord near or across hot surfaces Fix the assembly to the back of the stove with the four screws provided ASH PAN ASSEMBLY Remove ash pan from firebox Under ...

Страница 5: ...ORSPACE HEATED SHALL BE PROVIDED WHEN REQUIRED US Stove highly recommends your stove be installed by a qualified NFI US or WETT Canada technician To find the nearest qualified installer go to https nficertified org https www wettinc ca POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in an area that will favor the most efficient heat dis...

Страница 6: ...there is a horizontal run of flue pipe there must be at lease 18 of clearance between the pipe and the ceiling There also has to be floor protection under the horizontal run that extends 2 beyond each side of the flue pipe The chimney connector must not pass through an attic or roof space closet or similar concealed space a floor or a ceiling For Canadian installations where passage through a wall...

Страница 7: ...flex hose FOR USE IN MOBILE HOMES U S ONLY WARNING DO NOT INSTALL IN SLEEPING ROOM CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED INSTALL IN ACCORDANCE WITH 24 CFR PART 3280 HUD USE A FACTORY BUILT CHIMNEY THAT COMPLIES WITH UL 103 STANDARDS THEREFORE IT MUST BE A TYPE HT 2100 F USE A SPARK ARRESTER THE STOVE MUST BE ATTACHED TO THE STRUCTURE OF ...

Страница 8: ...ive temperatures in the appliance An inadequate draft may cause back puffing into the room and plugging of the chimney An inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints An uncontrollable burn or excessive temperature indicates an excessive draft CHIMNEY Your wood stove may be hooked up with a 6 factory built or masonry chimney I...

Страница 9: ...Combustible Ceiling Joists To Stove MASONRY CHIMNEY Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Be sure to the chimney cleaned before the stove is installed and operated When connecting the stove through a co...

Страница 10: ... opening with a 24 gage minimum sheet metal support Maintain the 6 153 mm space There should also be a support sized to fit and hold the metal chimney connector See that the supports are fastened securely to wall surfaces on all sides Make sure fasteners used to secure the metal chimney connector do not penetrate chimney flue liner METHOD D 2 51 mm Clearance to Combustible Wall Member Start with a...

Страница 11: ...oftwoods or too green or freshly cut hardwoods The following resources can assist in learning the burn characteristics of various species of wood http firewoodresource com firewood btu ratings or https forestry usu edu forest products wood heating The operation of this wood heater in a manner inconsistent with the owner s manual will void your warranty and is also against federal regulations Waste...

Страница 12: ...conditions for a chimney fire TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual EFFICIENCIES Efficiencies can be based on either the lower heating value LHV or the higher heating value H...

Страница 13: ... a bit longer depending on your chimney height and outdoor conditions After about a minute or once your fire is well started close the door and allow the kindling to ignite Once the kindling has burned down to a starter coal bed load the unit with approximately 29 lbs of fuel for the first high burn load 29 lbs HIGH After the first high burn load and the stove is well warmed up adjust the unit as ...

Страница 14: ...od moisture content will produce excess visible smoke and burn poorly AIR TUBES The air tubes assembled in this unit are designed to provide an accurate mix of secondary air to ensure the highest efficiency Any damage or deterioration of these tubes may reduce the efficiency of combustion The air tubes are held in position by screws or snap pins Locate these to either side of the tube and remove i...

Страница 15: ...s creosote deposit Leave the air control fully open for about 5 min every time you reload the stove to bring it back to proper operating temperatures The secondary combustion can only take place if the firebox is hot enough Always check for creosote deposit once every two months and have your chimney cleaned at least once a year If a chimney or creosote fire occurs close all dampers immediately Wa...

Страница 16: ...OVE OR EVEN HOUSE FIRE MAY RESULT This unit s door uses a 3 4 diameter rope gasket It is recommended that you change the door gasket which makes your stove door air tight once a year in order to ensure good control over the combustion maximum efficiency and security To change the door gasket simply remove the damaged one Carefully clean the available gasket groove apply a high temperature silicone...

Страница 17: ...ldment VG2520 BP 1 10 610968 Ashpan Housing VG2520 BL 1 11 610883 Leg Weldment VG2520 BL 4 12 25826 Hearth Plate 1 13 29216 Ash Pan 1 14 610068 Damper Slide Weldment 1 15 610066 Slide Retainer Weldment 1 16 86954 Damper Rod 1 17 893162 Wooden Knob 1 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIA...

Страница 18: ...1 893240 VG Complete Door Handle 1 2 891373 Door Hinge Pad Threaded 2 3 40880 Lg Square Cast Door 1 4 88082 Rope Gasket 3 4 1 5 893155 Glass 1 6 26314 Gasket Clamp 1 7 29213 Sides Glass Clamp 2 8 29212 Bottom Glass Clamp 2 9 11 10 8 7 6 5 1 2 3 4 5 4 3 2 6 7 8 1 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FR...

Страница 19: ...___ Engineer Name ______________________________________ License No _________________________________________ Company ____________________________________________ Telephone No _______________________________________ Stove Inspected Chimney Swept Items Replaced ______________________________________ Service 02 Date ________________________ Engineer Name ______________________________________ Licens...

Страница 20: ...20 2021 United States Stove Company NOTES ...

Страница 21: ... 2021 United States Stove Company 21 NOTES ...

Страница 22: ...________________ Service de 07 Date _______________________ Nom de l ingénieur __________________________________ N de licence _______________________________________ Compagnie _________________________________________ N de téléphone ____________________________________ Poêle Inspecté Cheminée balayée Articles Remplacé __________________________________ Service de 02 Date _______________________ N...

Страница 23: ...mplète 1 2 891373 Patin de charnière de porte fileté 2 3 40880 grande porte en fonte carrée 1 4 88082 Joint de corde 3 4 po 1 5 893155 Verre 1 6 26314 Joint de serrage 1 7 29213 Bride de verre sur les côtés 2 8 29212 Pince de verre inférieure 2 9 11 10 8 7 6 5 1 2 3 4 5 4 3 2 6 7 8 1 POUR CONSERVER LA COUVERTURE DE LA GARANTIE LES COMPOSANTS DOIVENT ÊTRE REMPLACÉS PAR DES PIÈCES D ORIGINE DU FABRI...

Страница 24: ...ent en cendrier VG2520 BL 1 11 610883 Soudure de jambe VG2520 BL 4 12 25826 Plaque de foyer 1 13 29216 Cendrier 1 14 610068 Soudure de glissière d amortisseur 1 15 610066 Soudure de retenue de glissière 1 16 86954 Tige amortisseur 1 17 893162 Bouton en bois 1 POUR CONSERVER LA COUVERTURE DE LA GARANTIE LES COMPOSANTS DOIVENT ÊTRE REMPLACÉS PAR DES PIÈCES D ORIGINE DU FABRICANT ACHETÉS AUPRÈS DE VO...

Страница 25: ...l air une fois par an afin d assurer un bon contrôle de la combustion une efficacité et une sécurité maximales Pour changer le joint de porte retirez simplement celui qui est endommagé Nettoyez soigneusement la rainure du joint disponible appliquez un silicone haute température vendu à cet effet et installez le nouveau joint Vous pouvez rallumer votre poêle environ 24 heures après avoir terminé ce...

Страница 26: ...eu que si le foyer est suffisamment chaud Vérifiez toujours le dépôt de créosote une fois tous les deux mois et faites nettoyer votre cheminée au moins une fois par an En cas d incendie de cheminée ou de créosote fermez immédiatement tous les registres Attendez que le feu s éteigne et que le chauffe eau refroidisse puis inspectez la cheminée pour déceler tout dommage Si aucun dommage ne se produit...

Страница 27: ...uits d air assemblés dans cette unité sont conçus pour offrir un mélange précis d air secondaire et assurer une plus grande efficacité Tout dommage ou détérioration de ces conduits peuvent réduire l efficacité de la combustion Les conduits d air sont maintenus en position par des vis ou par des goupilles de blocage Localisez et enlevez les des deux côtés du conduit pour le retirer et le remettre e...

Страница 28: ...votre feu est bien allumé fermez la porte et laissez le petit bois s enflammer Une fois que le bois d allumage a brûlé jusqu à un lit de charbon de démarrage chargez l unité avec environ 29 lb de carburant pour la première charge de combustion élevée 29 lbs HAUTE Après la première charge de combustion élevée et le poêle est bien réchauffé ajustez l unité au besoin pour un réglage de combustion moy...

Страница 29: ...ne respecterait pas les directives du présent manuel contrevient aux réglementations fédérales EFFICACITÉ Les rendements peuvent être basés sur la valeur calorifique inférieure LHV ou la valeur calorifique supérieure HHV du combustible La valeur calorifique inférieure est lorsque l eau quitte le processus de combustion sous forme de vapeur dans le cas des poêles à bois l humidité du bois brûlé qui...

Страница 30: ...raîchement coupés Les ressources suivantes peuvent aider à apprendre les caractéristiques de combustion de diverses essences de bois http firewoodresource com firewood btu ratings ou https forestry usu edu forest products wood heating Le fonctionnement de ce poêle à bois d une manière non conforme au manuel du propriétaire annulera votre garantie et est également contraire à la réglementation fédé...

Страница 31: ...accord de cheminée métallique Vérifiez que les supports soient fixés de façon sûre aux surfaces de la paroi sur tous les côtés Assurez vous que les éléments de fixation utilisés pour maintenir le raccord de cheminée métallique ne pénètrent pas dans le revêtement du carneau de la cheminée Cheminée en maçonnerie Supports de tôle d acier Conduit de cheminée Conduit de raccordement Le dégagement minim...

Страница 32: ...s de détérioration et de blocage Faites nettoyer la cheminée avant d installer et de faire fonctionner le poêle Lors du raccordement du poêle à travers une paroi combustible vers une cheminée en maçonnerie des méthodes spéciales sont requises Revêtement Porte de nettoyage étanche Protecteur de plancher Virole 305 mm 12 po des briques Mur inflammable Dégagement de 25 mm 1 po avec le pare feu Chevron...

Страница 33: ...xcessif CHEMINÉE Règle 2 10 3 Faîtage 3 pi min 2 pi min 10 pi Votre poêle à bois peut être raccordé à une cheminée préfabriquée de 6 po ou en maçonnerie Si vous utilisez une cheminée préfabriquée elle doit être conforme à la norme UL 103 ou CSA B365 il doit donc s agir d un type HT 2100 F Il doit être installé conformément aux spécifications du fabricant Tenez compte de l emplacement de la cheminé...

Страница 34: ...ÉE EN USINE ET CONFORME AUX NORMES UL 103 CELA DOIT DONC ÊTRE UN TYPE HT 2100 F UTILISEZ UN AGRESSEUR À ÉTINCELLES LE POÊLE DOIT ÊTRE FIXÉ À LA STRUCTURE DE LA MAISON MOBILE UTILISEZ LES DEUX 2 TROUS AU FOND DU PIÉDESTAL DE LA RADIATEUR POUR FIXER L APPAREIL AU SOL FIXATION DE L APPAREIL SUR UN PIÉDESTAL AU SOL Utilisez les trous désignés pour fixer l unité au sol FIXATION DE L APPAREIL AVEC LES P...

Страница 35: ...e plancher sous le conduit horizontal qui s étend de 2 po au delà de chaque côté du conduit de fumée Le raccord de cheminée ne doit pas traverser un grenier ou un espace sur le toit un placard ou un espace dissimulé similaire un plancher ou un plafond Pour les installations canadiennes où le passage à travers un mur ou une cloison de construction combustible est souhaité l installation doit être c...

Страница 36: ...t son remplacement par de l air plus froid Si nécessaire la distribution d air chaud du poêle peut être facilitée par l installation d un ventilateur Le poêle à bois ne doit pas être branché à un système de distribution d air chaud car une accumulation excessive de chaleur peut se produire Un poêle à bois ne doit jamais être installé dans un couloir ou à proximité d un escalier car il pourrait blo...

Страница 37: ... électrique avant de tenter l installation L ensemble souffleur est destiné à être utilisé uniquement avec un poêle qui est marqué pour indiquer une telle utilisation Ne faites pas passer le cordon d alimentation à proximité ou sur des surfaces chaudes Fixez l ensemble à l arrière du poêle avec les quatre vis fournies ASSEMBLAGE DU BAC À CENDRES Enlevez la casserole de cendre du foyer Sous le foyer ...

Страница 38: ...ection du système de cheminée existant ________________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et de l étanchéité de la porte Confirmer les dégagements aux combustibles selon les instructions d...

Страница 39: ...Taille VG2520 jambe 25 po 635 mm 27 po 686 mm 31 3 po 796 mm VG2520 piédestal 25 5 po 648 mm 27 po 686 mm 31 6 po 803 mm Chambre de combustion Largeur x Profondeur 22 65 po x 16 34 po 576 mm x 416 mm Volume Pieds cubes 2 73 pieds cubes Ouverture de la porte Largeur x Hauteur 18 po x 9 75 po 458 mm x 248 mm Porte en verre pyrocéramique Visualisation Largeur x Hauteur 16 po x 10 26 po 407 mm x 261 m...

Страница 40: ...re région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entraîner des dommages matériels des blessures corporelles ou même la mort Une installation incorrecte pourrait annuler votre garantie Conservez ces instructions dans un endroit sûr pour référen...

Отзывы: