STEP 3 Continued
Connecting the Remote Control Cable
Checks Before Exposure of the Source
Verify that the source guide tubes are attached to the outlet port.
Verify that the remote control connector assembly is correctly connected to the gamma-ray
source projector’s locking mechanism.
Ensure that no personnel are inside the Restricted Area or exposure room.
Ensure that the proper signs are posted and required warnings are in operation.
NOTE
If the remote control is fitted with an additional lock, release this lock and apply a forward
motion to control crank handle, as if exposing the source, until a resistance is felt. Release
the control crank handle and proceed with the next step.
CAUTION
Do not apply excessive force to the control crank handle in the expose direction as this could
cause the source assembly to move forward out of the stored position when the lock slide is
released. Do not retract the control cable and apply the control crank brake. Leave the
control crank and the control cable in a neutral tension position.
STEP 4
Projecting and Retracting the Source Assembly
Rotate the selector ring to the OPERATE position.
Ensure there is no tension/force in either direction on
the control cable.
1