![QSA Global SENTINEL SENTRY 330 Manual Download Page 11](http://html1.mh-extra.com/html/qsa-global/sentinel-sentry-330/sentinel-sentry-330_manual_3298146011.webp)
QSA Global, Inc.
40 North Avenue Burlington, MA 01803
888.272.2242
781.272.2000
qsa-global.com
Operations Manual
MAN-038 March 2019
Page 11 of 100
The SENTINEL SENTRY 110 and SENTRY 330 are also compliant for use with the Model 859 handling
cart.
Source transfers for the SENTINEL SENTRY 110 and SENTRY 330 can be performed with a Model 867
source changer.
Detachable bayonet fittings are provided with SENTINEL SENTRY 110 and SENTINEL SENTRY 330
gamma-ray source projectors. Use only bayonet, item number 86062-110 when using the SENTINEL
SENTRY 110 device and use only bayonet, item number 86062-330 when using the SENTINEL SENTRY
330 device.
Figure 3 – Bayonet Fitting Versions
Bayonet connectors shown in Figure 3 are:
Left:
SENTINEL SENTRY 330 Bayonet - Item number
86062-330
with large inner diameter and 330
marking. Compatible for use with Models 67606 and 90203 source guide tubes.
Right:
SENTINEL SENTRY 110 Bayonet - Item number
86062-110
with smaller inner diameter and 110
marking.
Compatible for use with Models 48906, 48907, 48930-X, 95020 and 95021 source guide tubes.