QCX assembly Rev 1.08
38
3.40
Install 10uF capacitors
There are six 10uF capacitors in the kit: C21, C22, C24, C37, C38 and C51. These are polarised
electrolytic capacitors and MUST be installed with the correct orientation! The capacitor
NEGATIVE wire must be installed in the hole indicated on the PCB silkscreen and the layout
diagram by the solid black bar; the POSITIVE wire must be installed in the hole indicated on the
PCB silkscreen and the layout diagram by the hollow bar and the + symbol.
Electrolytic capacitors are also supplied with one wire longer
than the other. The + wire is the longer wire, the
– wire is
the shorter one (see photo, right).