Power Application Controller
®
-32-
Copyright 2020 © Qorvo, Inc.
Rev 1.2
– Jan 17, 2019
When the temperature falls below 140°C minus the hysteresis, the
SOC.FAULT.TMPWARN
bit
will be cleared.
When the die temperature exceeds the fault threshold of 165°C, the
SOC.FAULT.TMPFAULT
bit is set to 1b. When this fault occurs, the PAC5527 is forced into hibernate mode and will stay
in hibernate mode until the push-button or wake-up timer (if configured) is received.
If the user has not configured the push-button or wake up timer to exit hibernate mode, the
PAC5527 will stay in hibernate mode until powered off and on again.