Flashing
Off
On
Light Status
STATUS INDICATORS
Refer to this table for the
following diagrams
Green Light
Red Light
Yellow Light
Valve Position
Valve Open
Green Light = On
Valve Closed
Red Light = On
Unknown Position
Green Light = Flashing
Red Light = Flashing
(alternating)
Alarm Indicator
Red Light = On
Yellow Light = Flashing/beeping once per second
To open the valve,
Push and hold until it beeps
The green light will flash while the valve opens.
The controller will beep when the valve is
completely open.
To close the valve,
Push and hold until it beeps
The red light will flash while the valve closes.
The controller will beep when the valve is
completely closed.
To mute the alarm,
Push and hold until it beeps
If the water sensor is still sensing water, the yellow
light will continue to flash. If it is no longer sensing
water then the yellow light will turn off.
OPERATION
Low Battery
Controller will beep, yellow light will turn on and valve
will close automatically.
Replace the battery at least every 12 months and
after any low battery warning.
POWER-SAVER OPERATION
When using battery power, the controller enters Power-
Saver operation. In Power-Saver operation, the lights
are turned off to extend battery life. Press any button
to temporarily turn on the lights to check the status of
the controller.
WARNING: If you open the valve after a low-
battery warning without first replacing the battery,
there may not be enough power left in the battery
to close the valve again if a water leak occurs.
Replace the battery immediately when a low-
battery warning occurs.
Power input:
9~12VDC (from DC adapter)
9V Alkaline Battery (backup)
Relay Contact:
N.C.
0.5A max @ 110VAC
1.0A max @ 30VDC
Valve Output:
5VDC (800mA max)
Sensor:
5VDC (5µA max)
Alarm:
85dBA
*Change battery every 12-months or after a low
battery warning (whichever comes first)
Technical Specifications:
QMI Manufacturing, Inc.
Coquitlam, B.C. Canada