Position Indicator

Closed

Open

Connect

To Controller

 F.I.P (female pipe thread)

both ends

Motor

 Check local plumbing codes and regulations before 
attempting to install the valve on your own.  Some 
jurisdictions prohibit or restrict do-it-yourself installations 
in residential plumbing.  If in doubt, hire a professional 
plumbing contractor to install the valve.

Tools required:

·  MIP (MNPT) fittings (x2) (compression¹ fittings or solder² 

fittings)

·  Adjustable wrenches (x2)
·  Tube/Pipe Cutter
·  Ruler
·  Marker
·  Teflon Tape
·  Protective eyewear

1  Compression fittings are rated for the outside diameter of the tube/pipe.  To 
connect a 1" valve to a ¾" copper pipe, use a 1"MIP x 7/8 compression fitting. For 
½"pipe, use 1"MIP x 5/8 compression fitting
2  Installation by professional plumbing contractor highly recommended when 
using solder fittings.

Compression fittings for copper tube/pipe

1. Shut off the water supply at the main shut-off valve
2. Open the Water Guardian™ valve using the Water Guardian™ 
controller
3. Apply Teflon tape to the male pipe threads on the fittings to 
provide a water-tight seal
4. Tighten the fittings into the valve using 2 wrenches. The 
Teflon tape from the previous step will ensure a watertight seal.
5. Remove the nuts and ferrules from the fittings
6. Measure the length of the valve with the fittings installed 
(without nuts & ferrules)
7. Read the instructions that came with the compression fittings 
to determine the length of pipe to cut out and fitting 
installation procedure.  If the fittings did not come with 
instructions:

a. Subtract the inside diameter of the tube from the length 
of the valve assembly from step 4. (The cut-out must be 

shorter than the valve assembly in order for the tube to 
extend inside the compression fittings)
b. Measure and mark the tube.
c. Double-check the measurement then cut the tube with 
the tube cutter.
d. Clean the tube ends of burrs and any dirt and debris.
e. Slide nut and ferrule over each tube end.
f. Insert the tube ends into fittings and tighten each nut 
with 2 wrenches.

8. Slowly turn on the main water supply and check for leaks.
9. Tighten any leaking fittings until the leaks stop.
10. Connect the valve motor to the controller (see controller 
installation instructions)

Solder fittings for copper tube/pipe

Installation of the valve using solder fittings should only be 
attempted by a qualified plumbing contractor.

Your new Water Guardian QMI.net system comes with the 
following product
 * motorized ball valve
 * wireless water sensor
 * wireless gateway
 * pad sensors
 * adaptors / screws  / fittings
 * wireless valves may be added

Operating Voltage:
Operating Current:

Max.Current:

Max. Pressure:

Size:

Max. Temperature:

Approvals/Certifications:

5V DC
80mA
500mA
120 P.S.I.
1" F.I.P.
60°C (domestic hot water)
NSF/ANSI Std. 61
IAPMO-U.P. Code
ASME A114.4.14
CSA B125

Ratings

Stainless Steel Motorized Ball Valve

Water Leak Protection System

Summary of Contents for water guardian

Page 1: ...Water Leak Protection System Système de protection contre les fuites d eau Sistema de protección contra fugas de agua NEW QMI net ...

Page 2: ...s 3 Insert Plug end of water sensor into water sensor connector see layout diagram 4 Place sensor end of water sensor on floor near appliance or where you expect a water leak may occur Additional sensors can be plugged into the socket on the sensor 1 Open the cover 2 Mount the box to the wall using 2 screws 5 Connect the wire from the valve into valve connector and tighten the screws see layout di...

Page 3: ...ht will turn off OPERATION Low Battery Controller will beep yellow light will turn on and valve will close automatically Replace the battery at least every 12 months and after any low battery warning POWER SAVER OPERATION When using battery power the controller enters Power Saver operation In Power Saver operation the lights are turned off to extend battery life Press any button to temporarily tur...

Page 4: ... ferrules 7 Read the instructions that came with the compression fittings to determine the length of pipe to cut out and fitting installation procedure If the fittings did not come with instructions a Subtract the inside diameter of the tube from the length of the valve assembly from step 4 The cut out must be shorter than the valve assembly in order for the tube to extend inside the compression f...

Page 5: ...r l embout capteur du capteur d eau sur le plancher près de l appareil où à l endroit où vous croyez qu il est possible qu il y ait une fuite d eau Des capteurs additionnels peuvent êtrebranchés dans le réceptacle du capteur 1 Ouvrir le couver 2 Fixer la boîte au mur à l aide des deux vis 8 Fermer le couvert 6 Brancher la pile et insérez la dans le compartiment des piles 7 Brancher l adapteur d al...

Page 6: ...NEMENT Pile faible Le régulateur émet un bip la lumière jaune s allumera et la soupape se ferme automatiquement Remplacer la pile au moins tous les douze mois et à la suite de tout avertissement de pile faible FONCTIONNEMENT ÉCONOMIE D ÉNERGIE Lorsque le dispositif est alimenté par pile lé régulateur passe en mode économie d énergie Lorsqu en mode de fonctionnement d économie d énergie les lumière...

Page 7: ...s instructions comprises avec les raccords à compression afin de déterminer la longueur des tuyaux à couper et la procédure d installation des raccords Si les instructions ne sont pas disponibles pour les raccords a Soustraire la longueur du diamètre de l intérieur du tube de la longueur de la soupape de l étape 4 Le résultat doit être inférieur à la soupape complète de sorte que le tube puisse s ...

Page 8: ...va de la FCC 3 Introducir el lado enchufable del sensor de agua en el receptáculo del sensor de agua ver esquema de instalación 4 Colocar el enchufe del sensor de agua sobre el piso cerca del aparato o en el sitio donde crea que es posible que haya una fuga de agua Sensores adicionales pueden conectarse en el receptáculo del sensor 1 Abrir la cubierta 2 Fijar la caja en la pared con la ayuda de lo...

Page 9: ...tonces el indicador luminoso amarillo se apagará FUNCIONAMIENTO Pila débil El regulador emite un bip el indicador luminoso amarillo se enciende y la válvula se cierra automáticamente Reemplazar la pila al menos cada doce meses y después de cada advertencia de pila débil FUNCIONAMIENTO ECONOMÍA DE ENERGÍA Cuando el dispositivo se alimenta por la pila el regulador pasa a modo economía de energía Cua...

Page 10: ...con los racores de compresión para determinar la longitud de las tuberías que deben cortarse así como el procedimiento de instalación de los racores Si las instrucciones para los racores no son disponibles a Restar la longitud del diámetro del interior del tubo de la longitud de la válvula de la etapa 4 El resultado debe ser inferior a la válvula completa de manera que el tubo pueda estirarse dent...

Reviews: