2 – Switch Command Line Interface
Groups and Commands
2-94
D000025-002 Rev. A
S
NOTE:
This command will set the MTU capability for both internal and
external switching. If the vlCap option is not specified, the command
defaults to the maximumVL(s) for the selected mtuCap. Calling this
function without an mtuCap designator displays the current value for
each port. A reboot is required to activate changes made with this
command.
ismIslSetSpeed
Allows the user to view and set internal port link speeds to 2.5 (SDR), 5.0 (DDR) or AutoNegotiate.
Syntax:
Options:
Sample Output:
NOTE:
This command works only on chassis supporting DDR links. This
command sets inter-switch link speeds to either 2.5, 5.0, or
AutoNegotiate. External ports remain configured to SDR rate (2.5)
and do not require special cabling configuration to function correctly.
Using this command without the option enable12xBit displays the
current values of the port. A reboot is required to activate changes
made with this command.
ismShowPStatThresh
Displays the port statistic thresholds.
Syntax:
Options:
ismIslSetSpeed [speed]
speed
1 = 2.5, 2 = 5.0, 3 = AutoNegotiate.
-> ismIslSetSpeed
L01S3Ba link speed is AUTO NEGOTIATE
L01S1Ba link speed is AUTO NEGOTIATE
L01S1Bb link speed is AUTO NEGOTIATE
L03S1Ba link speed is fixed 2.5 (SDR only device)
L03S3Ba link speed is fixed 2.5 (SDR only device)
ismShowPStatThresh
None.