Operating
screens
84
Operating manual HR9
– QS21XXXX
Turn conveyor settings
Motor configuration
Setting
Description
Nominal speed
Speed in meters per second at 50Hz
Nominal rotations per
minute
RPM at 50Hz
Reverse direction of
rotation
Yes = Invert rotary field of motor
Speeds
Setting
Description
Speed limits
The speed on the twist runner is limited to a maximum and minimum speed.
Speed is in meters per second
Acceleration is in seconds, from standstill to desired speed.
Deceleration is in seconds, from actual speed to standstill.
Lightgrid
Setting
Description
Beam settings
Start/end beam: First and last beam used for measurement.
Beam separation: Separation between beams(2.5 or 5).
Beam filter: the amount of time it takes to “accept” a beam
Object settings
Minimum object length for sampling
Minimum object separation. Minimum distance between objects
Product present window
Window in which the twistrunner registers a product present.
Offset data transfer
Offset data transfer from the twistrunner to the forming table. The longer
the offset, the long it takes for the forming table to start running
Minimum process quality
Minimum process quality before alarm & teach required
Minimum alignment
quality
Minimum alignment quality during the teach in process.