1.6.2
Storage file system
The storage file system of the SLATE106 device is
FAT
(FAT12).
The file system of the SLATE106 device can store about 976 KB of data file (.CFG, .PPK, .PAIRED) and applications files (.HTA, .EXE). | Firmware rev | FAT | used space |
available free space
|:--|:--|:--|:-- | 1.10.11 | FAT12 | 12 KB | 984 KB | 1.10.12 | FAT12 | 12 KB | 984 KB | 1.11.10 | FAT12 (fake FAT16) | 15 MB | 976 KB
Description of the main files which can be found in the file system | File type | File name | Average size
|:--|:--|:-- | Configuration file | APPLI.CFG | 2 KB | Configuration application | APPLI.HTA | 30 KB | SPE Desktop tool | SPE.EXE | 109 KB | Picture (propriety format) |
.PPK | 109 KB | Picture (propriety format) generated by SPE Desktop application | spe.ppk | 118 KB | Picture (propriety format) generated by the SMH300 hub or by
img2slate tool | hub.ppk | 118 KB | Software release | pictureframe-slate106-setup-1.XX.YY.rpk | < 220 KB | File created each time a PIN code has been set | .PINCODE |
197 KB | Mounting information (hidden directory) | /System Volume Information | 8 KB
The file system is not case sensitive (no difference between lower case and upper
case).*
It is possible to
modify the
APPLI.CFG
configuration file by executing the
APPLI.HTA
application
add or remove some .ppk picture
◬
After having added, modified or removed some file through the USB mass storage of the SLATE106 device, DO ALWAYS EJECT IT PROPERLY with your MS-Windows
before unplugging the USB cable to not corrupt the file.
◬
With firmware rev 1.10.11 and 1.10.12, in case the USB mass storage used space does not match at all the sum of the size of the file present on the file system and
prevent to add some ppk files, you can make an USB mass storage format:
Save all the file present on your SLATE106 device USB mass storage,
Format the SLATE106 device USB mass storage with your MS-Windows
File system type:
FAT
Allocation unit size:
4096
Bytes
Speed:
fast
When the format has completed, copy back the file saved on your computer.
Restore factory settings
To return to
SPE Desktop
configuration, after having already paired your SLATE106 device,
Unpair the SLATE106 device from the
SMH300
hub. For further information, refer to the
SMH300 User manual
on the Web site
Plug the SLATE106 device to a computer with an USB cable (
micro USB type B to USB
) and wait for the USB mass storage is mounted properly,
Delete the files
PAIRED
,
HUB.PPK
,
APPLI.CFG
Eject properly the SLATE106 device USB mass storage
.
Then wait for a while so that the USB mass storage is mounted back again,
Unplug the USB cable.
24