background image

4

5

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN

For additional information see the relevant datasheet of the module provided at www.q-cells.com.

PRODUCT LINE

Q.PRO-G4.X / Q.PRO EC-G4.X / Q.PRO BFR-G4.X

Q.PLUS BFR-G4.X

Type

Polycrystalline

Q.ANTUM

Area [m²]

1.67

1.67

Frame height [mm]

32

32

Weight [kg]

18.8

18.8

Max. system voltage V

SYS

 [V]

1000

1000

Max. reverse current [A]

20

20

Permissible temperature range

–40 °C to +85 °C (–40 °F bis +185 °F)

Junction box protection class

IP67 with bypass diode

Connector protection class

IP68

IP68

Fire protection class

C

C

Snow load [Pa]

1

5400

5400

Wind load [Pa]

1

4000

4000

Certificates

VDE Quality Tested

2

; CE-compliant; IEC 61215 (Ed.2) see page 9 et sqq.;

 

IEC 61730 (Ed.1) Application Class A

Test-load in accordance with IEC 61215   

2

 except Q.PRO EC-G4.X

Validity

These instructions are only valid for crystalline solar 
modules from the company Q CELLS. Q CELLS assumes 
no liability for damage resulting from failure to observe 
these instructions. 

 

Ä

Please observe the wiring and dimensioning of the 
system.

 

Ä

The installer of the system is responsible for compliance 
with all necessary safety regulations during set-up and 
installation.

Q CELLS assumes no liability on the basis of these 
instructions. Q CELLS is only liable in the context of 
contractual agreements or in the context of accepted 
guarantees. Q CELLS accepts no other responsibility for 
the functionality and safety of the modules. 

 

Ä

Please observe the instructions for any other sys-
tem components that may be part of the complete  
solar power system. It may be necessary to carry out a 
structural analysis for the entire project. 

Additional information for the Operator

 

Ä

Please keep this manual for the entire life of the solar 
power system.

 

Ä

Please contact your system supplier for information 
concerning the formal requirements for solar power 
systems.

 

Ä

Please be sure to contact the relevant local authorities 
and energy providers regarding regulations and permit 
requirements prior to installation of the solar power 

system. Your financial success depends on the fulfillment 

of these requirements. 

Other applicable documents

In addition to this Manual following technical information 
are relevant:

DOCUMENT TYPE

Product data sheet

Packaging and transport information

1 INTRODUCTION

2.1  Technical specifications

2 PLANNING

Fig. 1: 

External dimensions (in mm) and components for

 

Q.PRO-G4.X, Q.PRO EC-G4.X, Q.PRO BFR-G4.X, Q.PLUS BFR-G4.X

DETAIL A

16 mm

Junction bo×

Product label

1670 mm

4 × Fastening points (DETAIL A)

Cable with
connectors

Frame

1000 mm

32 mm

8 × Drainage holes

6 × Grounding points ø 4.5 mm

1000 mm

980 mm

150 mm

8.5 mm

24.5 mm

951 mm

Fig. 2: 

External dimensions (in mm) and components for Q.PRO-G4 (with 1170 mm fastening point distance)

DETAIL A

16 mm

8.5 mm

24.5 mm

Junction bo×

Product label

1170 mm

1670 mm

4 × Fastening points (DETAIL A)

Cable with

connectors

Frame

100 mm

1000 mm

951 mm

32 mm

8 × Drainage holes

6 × Grounding points ø 4.5 mm

1000 mm

Summary of Contents for Q.PLUS BFR-G4.X

Page 1: ...Valid for Africa Asia Europe Latin America South America Q PRO G4 X Q PRO EC G4 X Q PRO BFR G4 X Q PLUS BFR G4 X INSTALLATION AND OPERATION MANUAL ...

Page 2: ...bited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations In particular the installer as well as the operator of a module is responsible for compliance with all applicable statutory requirements and regulations Ä Ä Unless otherwise specified by any laws or regulations the...

Page 3: ... accepted guarantees Q CELLS accepts no other responsibility for the functionality and safety of the modules Ä Ä Please observe the instructions for any other sys tem components that may be part of the complete solar power system It may be necessary to carry out a structural analysis for the entire project Additional information for the Operator Ä Ä Please keep this manual for the entire life of t...

Page 4: ...free expansion and contraction due to temperature fluctuations Ä Ä Ensure that no mechanical stresses e g caused by vibrations twisting or expansion are generated on the module Ä Ä Ensure that the clamps and the mounting frame are compatible Clamp System Requirements Use customary clamps that satisfy the following require ments Clamp width 40 mm Clamp height compliant with a 32 mm frame height Cla...

Page 5: ...and middle of the clamp Describes the maximum module surface load vertical to the module surface regarding safety factors e g EUROCODE For this purpose the load value determined by load tests according to various criteria laminate overlay plastic deformation module failure and were divided with a safety factor The minimum calculated load value corresponds to the maximum permitted load 2 PLANNING 2...

Page 6: ...ground leaks or defective insulation Ä Ä Ensure that the maximum reverse current load capacity indicated in the data sheet is met In order to limit reverse currents that may occur we recommend using the following safety options 1 Layout with a limited number of parallel connected strings Without undertaking further current blocking measures a maximum of two module strings may be operated in parall...

Page 7: ...dules NOTE Module damage may occur Ä Ä Do not install modules near flammable gas vapors Ä Ä Do not install modules in close proximity to air conditioning systems 3 1 Safety and transport 3 INSTALLATION DANGER Risk of fatal injury due to electric shock Ä Ä Block off the installation zone Ä Ä Keep children and unauthorized individuals away from the solar power system DANGER Risk of fatal injury due ...

Page 8: ...ult in life threatening injuries The danger increases when several modules are connected in series Ä Ä Please be aware of that the entire open circuit voltage is active even at low levels of solar irradiation Ä Ä Please follow the valid national regulations and safety guidelines for the installation of electrical devices and systems Ä Ä Please make sure to take all necessary safety precautions Wit...

Page 9: ...ate and qualified tools of the manufacturer Tyco Amphenol or Multicontact 2 Cover the modules to be disconnected 4 2 Electrical installation safety 4 ELECTRICAL CONNECTION Ä Ä Use solar cables for the connection at the junction box outlet Ä Ä Use the same inverter compatible plugs SOLAR NOTE Module damage may occur Ä Ä Ensure that the cabling is not under stress Ä Ä Ensure that the cables do not r...

Page 10: ... Protective Grounding Ä Ä The modules must be grounded in accordance with the local statutory regulations Functional grounding When using an installation tilt of 5 a functional grounding at the negative generator conncetion must be implemented Ä Ä Ensure that the difference of potential between the negative generator connection and the PE N of every MPP tracker of the respective inverters is 0 V Ä...

Page 11: ...r without taking adequate security precautions Ä Ä Please commission a trade specialist Clean the modules as follows NOTE Module surface damage may occur Ä Ä Remove snow and ice carefully without force e g with a very soft broom Ä Ä Do not scratch off dirt Ä Ä Rinse dirt dust leaves etc off with lukewarm water or use an alcohol based glass cleaner Do not use abrasive detergents or tensides Ä Ä Use...

Page 12: ... Sonnenallee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 34946699 23222 FAX 49 0 34946699 23000 EMAIL service q cells com WEB www q cells com Subject to change without notice Hanwha Q CELLS Installation manual G4 modules_2016 02_Rev03_EN ...

Reviews: