background image

16

17

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN

17

16

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Ensure correct polarity.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Be sure to maintain the time intervals as 

specified by the inverter manufacturer 

between switching off the inverter and 
beginning any further work.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Never unplug the cable when under load.

1.

 Switch off the inverter.

OFF

EN

3.

 Switch off the DC circuit breaker.

 

Ä

Disconnect plugs by the use of 

appropriate and qualified tools of 

the manufacturer Tyco, Amphenol or 
Multicontact.

2.

 Cover the modules to be disconnected.

4.2  Electrical installation safety

ELECTRICAL CONNECTION

 

Ä

Use solar cables for the connection at 
the junction box outlet. 

 

Ä

Use the same, inverter-compatible plugs.

SOLAR

NOTE

! Module damage may occur!

 

Ä

Ensure that the cabling is not under 
stress.

 

Ä

Ensure that the cables do not run 
between module and subconstruction 

(danger of pinch).

 

Ä

Do not connect modules with different 
orientations or angles of inclination in 
the same string.

 

Ä

Ensure for a tight connection between 
the plugs. Plugs click together audibly.

Klick

DE

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Ensure that all electrical components are 
in a proper, dry, and safe condition.

• 

Standard wiring with a return cable.

Inverter

EN

4.3  Connection of modules

ELECTRICAL CONNECTION

Summary of Contents for Q.PLUS BFR-G4.X

Page 1: ...Valid for Africa Asia Europe Latin America South America Q PRO G4 X Q PRO EC G4 X Q PRO BFR G4 X Q PLUS BFR G4 X INSTALLATION AND OPERATION MANUAL ...

Page 2: ...bited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations In particular the installer as well as the operator of a module is responsible for compliance with all applicable statutory requirements and regulations Ä Ä Unless otherwise specified by any laws or regulations the...

Page 3: ... accepted guarantees Q CELLS accepts no other responsibility for the functionality and safety of the modules Ä Ä Please observe the instructions for any other sys tem components that may be part of the complete solar power system It may be necessary to carry out a structural analysis for the entire project Additional information for the Operator Ä Ä Please keep this manual for the entire life of t...

Page 4: ...free expansion and contraction due to temperature fluctuations Ä Ä Ensure that no mechanical stresses e g caused by vibrations twisting or expansion are generated on the module Ä Ä Ensure that the clamps and the mounting frame are compatible Clamp System Requirements Use customary clamps that satisfy the following require ments Clamp width 40 mm Clamp height compliant with a 32 mm frame height Cla...

Page 5: ...and middle of the clamp Describes the maximum module surface load vertical to the module surface regarding safety factors e g EUROCODE For this purpose the load value determined by load tests according to various criteria laminate overlay plastic deformation module failure and were divided with a safety factor The minimum calculated load value corresponds to the maximum permitted load 2 PLANNING 2...

Page 6: ...ground leaks or defective insulation Ä Ä Ensure that the maximum reverse current load capacity indicated in the data sheet is met In order to limit reverse currents that may occur we recommend using the following safety options 1 Layout with a limited number of parallel connected strings Without undertaking further current blocking measures a maximum of two module strings may be operated in parall...

Page 7: ...dules NOTE Module damage may occur Ä Ä Do not install modules near flammable gas vapors Ä Ä Do not install modules in close proximity to air conditioning systems 3 1 Safety and transport 3 INSTALLATION DANGER Risk of fatal injury due to electric shock Ä Ä Block off the installation zone Ä Ä Keep children and unauthorized individuals away from the solar power system DANGER Risk of fatal injury due ...

Page 8: ...ult in life threatening injuries The danger increases when several modules are connected in series Ä Ä Please be aware of that the entire open circuit voltage is active even at low levels of solar irradiation Ä Ä Please follow the valid national regulations and safety guidelines for the installation of electrical devices and systems Ä Ä Please make sure to take all necessary safety precautions Wit...

Page 9: ...ate and qualified tools of the manufacturer Tyco Amphenol or Multicontact 2 Cover the modules to be disconnected 4 2 Electrical installation safety 4 ELECTRICAL CONNECTION Ä Ä Use solar cables for the connection at the junction box outlet Ä Ä Use the same inverter compatible plugs SOLAR NOTE Module damage may occur Ä Ä Ensure that the cabling is not under stress Ä Ä Ensure that the cables do not r...

Page 10: ... Protective Grounding Ä Ä The modules must be grounded in accordance with the local statutory regulations Functional grounding When using an installation tilt of 5 a functional grounding at the negative generator conncetion must be implemented Ä Ä Ensure that the difference of potential between the negative generator connection and the PE N of every MPP tracker of the respective inverters is 0 V Ä...

Page 11: ...r without taking adequate security precautions Ä Ä Please commission a trade specialist Clean the modules as follows NOTE Module surface damage may occur Ä Ä Remove snow and ice carefully without force e g with a very soft broom Ä Ä Do not scratch off dirt Ä Ä Rinse dirt dust leaves etc off with lukewarm water or use an alcohol based glass cleaner Do not use abrasive detergents or tensides Ä Ä Use...

Page 12: ... Sonnenallee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 34946699 23222 FAX 49 0 34946699 23000 EMAIL service q cells com WEB www q cells com Subject to change without notice Hanwha Q CELLS Installation manual G4 modules_2016 02_Rev03_EN ...

Reviews: