16
17
INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN
INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN
17
16
DANGER
! Risk of fatal injury due to electric
shock!
Ä
Ensure correct polarity.
DANGER
! Risk of fatal injury due to electric
shock!
Ä
Be sure to maintain the time intervals as
specified by the inverter manufacturer
between switching off the inverter and
beginning any further work.
DANGER
! Risk of fatal injury due to electric
shock!
Ä
Never unplug the cable when under load.
1.
Switch off the inverter.
OFF
EN
3.
Switch off the DC circuit breaker.
Ä
Disconnect plugs by the use of
appropriate and qualified tools of
the manufacturer Tyco, Amphenol or
Multicontact.
2.
Cover the modules to be disconnected.
4.2 Electrical installation safety
4
ELECTRICAL CONNECTION
Ä
Use solar cables for the connection at
the junction box outlet.
Ä
Use the same, inverter-compatible plugs.
SOLAR
NOTE
! Module damage may occur!
Ä
Ensure that the cabling is not under
stress.
Ä
Ensure that the cables do not run
between module and subconstruction
(danger of pinch).
Ä
Do not connect modules with different
orientations or angles of inclination in
the same string.
Ä
Ensure for a tight connection between
the plugs. Plugs click together audibly.
Klick
DE
DANGER
! Risk of fatal injury due to electric
shock!
Ä
Ensure that all electrical components are
in a proper, dry, and safe condition.
•
Standard wiring with a return cable.
Inverter
EN
4.3 Connection of modules
4
ELECTRICAL CONNECTION