[ Table 7-11 : Battery Operation General Events List ]
P01P
Unknown
Unregistered Failure
It is an unregistered fault. Turn off and restart
the system. Please contact the Hansol
Technics Service –Hotline, if an error occurs
continuously.
P03P
DSP-EMG
TRIP P
DSP-Emergency
Trip Protection
Please check emergency switch.
Type : PROTECTION
WEB Display
HMI Display
Description
Measures
7.7.3 System General Events (Protection)
B46P
BAT5 CEL
OT P
BAT5 Cell Over Temp
Protection
When the maximum cell temperature is
above protection level, thus terminating the
system.
Automatically returns to normal when the
maximum cell temperature goes below
the limit value.
WEB Display
HMI Display
Description
Measures
B47P
BAT5 COM P
BAT5 Communication
Protection
Power reset of the system is required. If the
symptom persists after reset, replace the
cable connecting the Battery pack and the
INVERTER. After replacement, repair of BMS
or PCS Control Board is necessary.
B48P
BAT5 ADD P
BAT5 Additional
Protection
Power reset of the system is required.
If the symptom still occurs after reset, repair
of BMS or PCS Control Board is necessary.
P11P
ADC P
ADC Measure Error
Protection
Please turn off and restart the system.
If an error occurs repeatedly, it is necessary
to replace the Control Board.
P12P
DSPM
UPDATE P
DSP Master Remote
Update Fail Protection
Please update DSP Master software again.
P13P
DSPS
UPDATE P
DSP Slave Remote
Update Fail Protection
Please update DSP Slave software again.
P13P
DSPS
UPDATE P
DSP Slave Remote
Update Fail Protection
Please update DSP Slave software again.
53