Battery Data (DC)
Max. input total power
Max. input power per string
Max. input voltage
Min. input voltage/Initial input voltage
MPPT voltage range
Max. input current per string
Max. input short circuit current for each MPPT
Max. INVERTER backfeed current to the array
Number of independent MPPT trackers
Number of DC inputs pairs for each MPPT
Connection type
Over voltage Category
6.6 kWp
3.3 kWp
550 V
125 V / 150 V per string
125 V ~ 500 V
15 A
20 A
316 A (0.153 ms)
2
2
MC4 Type
II
Battery nominal capacity
Battery short circuit current
Battery usable capacity
Battery voltage range / nominal voltage
Max. discharge current
Max. charge current
Max. charge power
Max. discharge power
Max. input / output short circuit current
Battery technology
DC/DC converter technology
Over voltage Category
1 Battery pack
2 or more Battery pack
4.0 kWh
3.6 kWh
9.8 A
2 kWh
4.0 kWh x Pack
3.6 kWh x Pack
17 A
3 kWh
30 A
176.4 Vdc ~ 225.12 Vdc / 203.84 Vdc
17 A
3 kWh
227 A / 278 A (1.003 ms / 1.222 ms)
Li-Ion
Non-Isolated
II
PV Data (DC)
Grid Data (AC)
Rated power (at 230V, 50 Hz)
Max. apparent AC power
Nominal voltage / range
Rated power frequency / range
Max. current
Max. over-current protectionent
Max. output fault current
Adjustable power factor range
Feed-in phases / connection phases
Total Harmonic Distortion.
(Total harmonic factor of the output current with total
harmonic factor of the AC voltage < 2%,
and AC power > 50% of the rated power)
Over voltage Category
III
4.6 kW
4.6 kVA
230 V / 184 V ~ 264 V
50 Hz / 47.5 Hz ~ 51.5 Hz
20 A
32 As
84.5 A (Peak), 0.956 ms
0.8 lagging to 0.8 leading
1 / 1
5%
2.1.2 Technical Specifications