Shutdown
To keep the PC200 valve in good condition do these steps at the end of each day:
1.
Remove the static mixer.
2.
Purge fresh material through the valve until both material streams are
completely clean and have no cross-contamination.
3.
Clean all material off of the manifold nozzle.
4.
Put a night cap (PVA part number 214-3832) on the manifold nozzle.
5.
Release the pressure in the system, refer to the workcell manual.
Figure 6: PC200 Night Cap
NOTE: Refer to Sections 6 and 7 for part reference numbers.
Maintenance
Interval
Action
Daily
•
Examine the material outlets for contamination and cured
material.
Weekly
•
Examine component A and B material containers or cartridges
for signs of cured or dried material.
Before you do maintenance on this valve, make sure you have a spare parts kit. If any
parts have wear or damage, replace them with new parts from the kit.