Periodic Maintenance
How to Replace a Static Mixer
Remove the old static mixer and do the steps in Section 3.2 to install a new static mixer.
How to Replace Lip Seals
The PC200 valve will require lip seal replacement periodically. The interval between seal
replacement varies widely depending on duty cycle, material type, and day to day care
of the valve. It is highly recommended that spare parts kits and a tool kit be on hand for
fast and easy seal replacement. Refer to Section 9 for spare parts kits
information.
For a more extensive valve rebuild, refer to Sections 6 and 7 for a complete bill of
materials and exploded drawings.
Seal Plate Lip Seals
1.
Disassemble and clean the valve.
2.
Do steps 1-8 in Section 4.3 and replace the lips seals in the seal plate.
3.
Refer to Section 4.3 to assemble the valve again.
Fluid Section Lip Seals
1.
Disassemble and clean the valve.
2.
Do steps 1-11 in Section 4.3 and replace the lips seals in the seal plate.
3.
Refer to Section 4.3 to assemble the valve again.
How to Replace Valve Rods
1.
Disassemble and clean the valve.
2.
Do steps 1-2 in Section 4.3 and replace the rods.
3.
Refer to Section 4.3 to assemble the valve again.
How to Replace Sleeve Bearings
1.
Disassemble and clean the valve.
2.
Do steps 1-7 in Section 4.3 and replace the sleeve bearings in the separation
block.
3.
Refer to Section 4.3 to assemble the valve again.