Technical Specifications
Weight
Approximately 9.98 kg (22-25 lbs.)
Material inlet
3/4’’ Sanitary Fitting
Material outlet
Bell Style (for 1K applications,
we have a 1/4” NPT option)
Figure 57: Technical Specifications
Troubleshooting
This section is designed to help solve problems before you call PVA. Refer to this section if
a mechanical or electrical problem occurs.
Troubleshooting Problem
Possible Cause
Corrective Action
Lubrication fluid is
discolored
•
Opaque fluid is a sign of
failed lip seals
•
Replace the lip seals and
the lubrication fluid
The metering rod does not
refill
•
Material pressure is too low
•
Lip seals are damaged
•
Increase the material
pressure
•
Replace the lip seal(s) and
replace the lubrication
fluid
Material leaks from the
valve body
•
The valve gasket is
damaged
•
Replace the valve gasket
The valve does not shut off
•
The valve gasket is
damaged
•
The valve pistons have
material contamination
•
Replace the valve gasket
•
Clean the valve pistons
Material contamination
•
The valve gasket is
damaged
•
Clean the fluid block,
replace the valve gasket,
replace the lubrication
fluid
The material has air in it
•
Valve was not correctly
purged
•
Purge the valve until the
metering rod reaches its
full travel, the machine
may error out, and all the
valve to fully refill