Maintenance
Schedule
Action
Daily
At the end of each day, remove the valve tip and clean off any
extra material. If it is a two-part material, be careful not to mix
the materials or they will cure. install a nightcap.
As Necessary
The fluid distribution block holds lubrication fluid. There is a fill
line on the oil window to show the necessary fluid level. If the
lubrication fluid is below the fill line, add more.
Figure 55: Preventative Maintenance Schedule
Spare Parts
Below, the spare parts are highlighted and numbered. Refer to your Bill of Materials and
schematic for specific options on your pump.
The spare parts kit is part number
B82-MR2
.
Item Description
Part Number
Quantity Notes
Lip Seals, Urethane
9505K15
2
Lubrication Fluid
206-994
8 oz. bottle
Clamp Gasket, Teflon
43315K22
4
Valve Gasket, Viton
614-12157-1
1
O-ring, -012, Buna
VLV-012B
4
O-ring, -012, Kalrez
VLV-012K
2
O-ring, -014, Buna
VLV-014B
4
O-ring, -021, Kalrez
VLV-021K
4
O-ring, -024, Buna
VLV-024B
4
O-ring, -040, Buna
VLV-040B 1
Figure 56: B82-MR2 Spare Parts List
Contact PVA for information on replacement parts or to order.