Nixie Tube Clock ‘Nixie QTC+’
2 (01 October 2018)
www.pvelectronics.co.uk
- 13 -
Plug in the power supply, and then test using a DC voltmeter:
Touch the black probe on the GND test point and the red probe on
the 5V test point. The voltage should measure between 5.6 and 5.9
Volts. If not, disconnect power and check your work. Do not
proceed with the assembly until the error is corrected. Once the
test is completed, disconnect the power.
4.3
High Voltage Generator components.
Socket for IC2
R1, R2 (4.7 KΩ)
R3, R4 (390 KΩ)
R5 (300 KΩ)
C3 (1uF)
C4 (220uF)
Q1 (IRFD220)
L1 (100uH Inductor)
D5 (UF4004)
Summary of Contents for Nixie QTC Plus
Page 57: ...Nixie Tube Clock Nixie QTC 2 01 October 2018 www pvelectronics co uk 57 ...
Page 59: ...Nixie Tube Clock Nixie QTC 2 01 October 2018 www pvelectronics co uk 59 13 CIRCUIT DIAGRAM ...
Page 60: ...Nixie Tube Clock Nixie QTC 2 01 October 2018 www pvelectronics co uk 60 ...
Page 61: ...Nixie Tube Clock Nixie QTC 2 01 October 2018 www pvelectronics co uk 61 ...