User Manual
PT-PMS-62S
35
8.2
RS232 Communication Command
Communication protocol:
RS232 Communication Protocol
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
Note:
In the commands, “[”and “]” are symbols for easy reading and do not need to be
typed in actual operation.
Please remember to end the commands with the ending symbols “.” or “;”.
Type the command carefully, it is case-sensitive.
8.2.1
Device Control
Command
Description
Feedback Example
PWON.
Power on system.
PWON
PWOFF.
Power off system. Turn off HDBaseT
power supply.
PWOFF
STANDBY.
System standby. Press any button to
awake.
STANDBY
/*Type;
Report system model.
PT-PMS-62S
/^Version;
Report firmware version.
V1.0.0
/%Lock;
Lock front panel buttons.
System Locked
/%Unlock;
Unlock front panel buttons.
System Unlock!
%9964.
Report IP address.
IP:192.168.0.178
USBUpdata:[x].
Upgrade the 3458 IC of the port [x].
X
Port
1~6
Input port
7~8
Output port
%9961.
Report the system locking status.
System UnLock/Lock!
%9962.
Report the system power status.
PWON/PWOFF
%0911.
Reset to factory default.
Note:
The switcher must be restarted after
factory reset to ensure signal output.