Leak detected at
filters
O-ring damaged, deteriorated or
incorrectly installed
O-rings dry
Filter cartridge not centered
Remove the sump, wipe the
O-ring and threads clean.
Ensure the O-ring is fitted
properly, then reinstall
Lubricate o-rings with suitable
sealant
Remove sump, check for
cartridge damage, re-assemble
ensuring cartridge is centered
Red lamp blinks
and buzzer sounds
Lamp has reached or nearing the
maximum lamp life
Lamp is disconnected or faulty
Replace lamp on or before lamp
counter reached 0.
Check lamp connection, replace
if needed
Display flashing
Power interruption
Reset ballast
Error Code ‘A3’ on
ballast
Ballast countdown has reached 0,
lamp life expired
Replace lamp
Troubleshooting Guide