Installation & Operation Manual
Copyright © Puretec Pty Ltd 2018
Installation Requirements
•
This unit is intended for indoor installation (must be protected from weather, frost,
water and have adequate ventilation).
•
Cold water line only.
•
Power supply: AC 240V | 50Hz
•
Supply pressure: 300-875 kPa. Install pressure limiting valve if pressure exceeds
500 kPa.
Note: For point of entry installations an approved dual check backflow
prevention device must be installed.
•
Supply temperature 3° - 52°C.
•
Alternative fittings may be required if being connected to anything other than
25mm threads.
Note: Only use thread seal tape. Do not use liquid sealant
•
Ensure the water supply flow rate does not exceed the rated maximum of the
Hybrid system.
•
Ensure the electrical power supply to the Hybrid system is sufficient, allowing for
other appliances that may be connected to the circuit eg pump, and ensuring it is
surge protected, and protected against brown-outs. If in doubt, please consult a
qualified electrician.
•
Use unions at pipe connections to enable easy removal and servicing. Use sufficient
tape to ensure airtight seal and do not over tighten. To prevent strain on the unit
always support heavy inlet and outlet pipes.
•
Where the water being treated contains unusually high levels of dissolved solids
particularly hard water, iron, manganese or biological organisms, a deposit build up
on the quartz sleeve may occur over time. Maximum recommended parameters are
as follows:
Iron
less than 0.3 mg/L
Hydrogen Sulfide
less than 0.05 mg/L
Suspended Solids
less than 10mg/L
Manganese
less than 0.05 mg/L
Hardness
less than 110mg/L
Installation Requirements