2.6 Electrical Power
Power Module
Your press kit will come with an appropriate power cable
for your location.
Power Draw:
8 amps while heating, 2 amps continuous
draw.
Emergency Stop:
In the event of an emergency, pushing the
E-Stop button disconnects power to the heaters and the
solenoid valve. Disconnecting power to the solenoid valve will
cause the plates to immediately retract so long as an air
supply (10 PSI minimum for the Pikes Peak and 20 PSI
minimum for the Longs Peak ) is supplied.
Fuse Replacement
1.
Ensure the power switch is in the OFF position and remove the
power cable. Wait for at least 60 seconds.
2.
Using a small screwdriver, gently pry loose and remove the
fuse holder.
(Figures 1A, 2A)
3.
Carefully replace the fuses [Fast Acting 250V, 10A, 5mm x
20mm].
(Figure 3A)
Figure 1A
Figure 2A
Note:
Your product serial label will indicate if
your press is rated for 120/240VAC or just
120VAC. The fuses on this machine should
now under normal operation. Should your
fuses blow, it is likely that there is a problem
with the supplied power.
Figure 3A