background image

Summary of Contents for CP1I5

Page 1: ......

Page 2: ...t to suporte pumatronix com The information contained in this document is subject to change without notice Pumatronix reserves the right to modify or improve this material without obligation to notify...

Page 3: ...lligent Transport Systems ITS in which Pumatronix products such as the ITSCAM FF 600 line are used This line captures images of vehicles in places whose chosen processing infrastructure is embedded pe...

Page 4: ...ence of an electrical grounding system may cause the ITSCAM FF 600 to burn and the user must correctly ground the product Loss of Warranty Appropriate conductors must be used with a gauge compatible w...

Page 5: ...ype Estimated range in meters ITSCAM FF 600 CP1I5 1636x1220px HDR Integrated Motorized 10 to 37 meters 13 55mm The estimated range is set according to the selected lens and identifies in which distanc...

Page 6: ...ection 16 Antenna Connection 17 Antennas for 4G and 3G 17 GPS Antenna 17 Wi Fi Antenna 18 Software Specifications 18 Access to ITSCAM 600 18 Multiple Users 18 ITSCAMPRO M vel Plugin Access 18 Image Ca...

Page 7: ...ular Configuration 26 First Access to ITSCAM 600 Device 26 First Access to the ITSCAMPRO M vel Plugin 27 Care and Maintenance 27 Firmware Upgrading 28 ITSCAM FF 600 Update via Web Interface 28 Restric...

Page 8: ...dization even when there are significant variations in light conditions This is possible by switching the image configuration profiles Profile changes are made by the equipment based on the image leve...

Page 9: ...s ITSCAM FF 600 line provides 2 Gigabit Ethernet ports on the back panel of the ITSCAM 600 device to facilitate connectivity at monitoring points and allow remote and simultaneous access for multiple...

Page 10: ...about the equipment setup are stored inside the image files in the JPEG field for the storage of comments The images can receive the overlap of a stripe with configurable content and for each photo re...

Page 11: ...pumatronix com Figure 5 Pole fastener 1 Pole support 2 Stainless steel clamp Framing adjustment with movement of the joint at equipment base Figure 6 Possible adjustments to the joint at equipment ba...

Page 12: ...V Antenna male SMA connector 5 SIM Card connector for Micro SIM 15mm x 12mm x 0 76mm 6 2 Gigabit Ethernet RJ 45 connector EIA TIA 568A standard indicated 7 USB 2 0 host 2 0 host 8 SD Card Slot for mic...

Page 13: ...IEC 61000 4 2 AEC Q100 002 and 30 kV by air IEC 61000 4 2 AEC Q100 002 Fast electrical transient EFT protection DC supply direct current peak at 10 1000 s up to 53 3 A 5 ISO 7637 and IEC 61000 4 4 Inr...

Page 14: ...h gain straight external antennas 850 MHz 900 MHz 1 8 GHz 1 9 GHz 2 1 GHz CDMA DCS EDGE GPRS GSM HSPA PCS UMTS WCDMA 824 960 MHz 1 71 2 17 GHz 1 42 dBi 1 91 dBi 2 51 dBi 3 23 dBi 2 89 dBi Certificates...

Page 15: ...ilar structure to avoid the unwanted infiltration of liquids in the bundle and the consequent ITSCAM FF 600 connections oxidation Power Connections Electrical and signal connections are made to the IT...

Page 16: ...N Red P6 IO1 Yellow IOs Connection of signals to the illuminator IO1 Orange P8 IO2 Blue IO2 Green P10 IO3 Blue White Connection of configurable input and or output signals IO3 Red White P7 IO4 Black I...

Page 17: ...ble to apply up to two illuminators connected to the Connection Board Applying illuminators is optional and requires maintaining a minimum distance of 50 centimeters from the image capture device Figu...

Page 18: ...d processing device The screen printing on the equipment back panel assists in identifying connectors for the antennas Figure 10 SMA connectors for the antennas in the ITSCAM device 600 1 Wi Fi Antenn...

Page 19: ...Access to ITSCAM 600 ITSCAM 600 has a web interface for evaluating the images generated and performing configurations such as Network OCR Trigger For accessing the network it is required to inform Us...

Page 20: ...fter defining the ITSCAM FF 600 image capture flow the Multiple Exposures functionality can be enabled per request This technology allows setting up two to eight sequential images with variation in th...

Page 21: ...ital post processing Gain which allows the images to lighten or darken When using Multiple Exposures or photos the first capture allows the non reflective plates to be clearly visualized and the secon...

Page 22: ...captures with artificial lighting nighttime An example architecture of ITSCAM FF 600 settings profiles is presented in diagram and indicating web interface parameters Adjustments to the ITSCAM FF 600...

Page 23: ...hicle license plate read automatically If the user has permission to change the plate an edit button is displayed next to it Temporal information of image acquisition capture date and time Location da...

Page 24: ...n Military Police system PM MG Integration of ITSCAMPRO M vel with Military Police of Minas Gerais PM MG system Detecta SP Integration of ITSCAMPRO M vel with Detecta SP system SPIA PRF Integration of...

Page 25: ...t be considered In sequence the installation diagram for capturing two lane images indicates the ideal equipment position in relation to the monitored road Positioning on the track center minimum d 10...

Page 26: ...work interface ETH2 is disabled Eth1 Port Setting Default Value IP Address 192 168 0 254 Maintenance IP Address 192 168 254 254 Netmask 255 255 255 0 ITSCAM FF 600 connectivity Check in the Wi Fi Netw...

Page 27: ...y Channel and Authentication Protocol that will be applied to the distribution of the Wi Fi connection 2 Enter the IP Address and Subnet Mask for the DHCP Server by determining the address range for t...

Page 28: ...tup Equipment connected to the same data network as the ITSCAM FF 600 device by the address for external access or by devices that have the Android iOS application installed The default address for ac...

Page 29: ...Keep the ITSCAM FF 600 device inactive during the upgrade process ensuring that it is not requested by any service or other equipment on the network in which it is installed 2 Keep the ITSCAM FF 600...

Page 30: ...tarted or turned off and that it is not being requested by any service or other equipment on the network during the process This security is required when performing this procedure to prevent the upda...

Page 31: ...which indicates that the recovery process is undergoing 10 Verify the status LED blinking green which indicates the recovery is done 11 Power off the board 12 Remove the SD card from the card slot and...

Page 32: ...or water on the glass of the protective box so that it is possible to remove excess dirt adhered to the surface 15 Use a soft cloth that does not loosen fibers to remove dirt moving the cloth in only...

Page 33: ...Showing signs of tampering with security seals 7 Showing signs of opening and modification made by the Customer in points of the product not authorized by Pumatronix 8 Damage caused by accidents falls...

Page 34: ......

Reviews: